Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 193 | 223 |
| b | 123 | 145 | |
| c | 153 | 185 | |
| d | 111 | 123 | |
| e | 21 | 17 | |
| f | 6 | 8 | |
| g | 288 | 317 | |
| h | 127 | 140 | |
| PG | 29 | 36 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 193 | 223 |
| b | 123 | 145 | |
| c | 153 | 185 | |
| d | 111 | 123 | |
| e | 21 | 17 | |
| f | 6 | 8 | |
| g | 288 | 317 | |
| h | 127 | 140 | |
| PG | 29 | 36 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 193 | 223 |
| b | 123 | 145 | |
| c | 153 | 185 | |
| d | 111 | 133 | |
| e | 21 | 17 | |
| f | 6 | 8 | |
| g | 288 | 317 | |
| h | 127 | 140 | |
| PG | 29 | 36 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MORE
Choosing a Waterproof Industrial Plug for wet and dusty work environments is usually not a one-step decision. In real pr...
READ MORE
Upgrading industrial electrical setups often involves considering new socket configurations. Incorporating a Wall Mounte...
READ MORE
A Wall Mounted Industrial Socket and a 240V Industrial Socket are used in workshops, factories, and big work areas. They...
READ MORE