| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.8 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 91 | 101.8 | |
| i | 45 | 58 | |
| j | 51.2 | 63 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.8 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 91 | 101.8 | |
| i | 45 | 58 | |
| j | 51.2 | 63 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 32.2 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 92.4 | 101.8 | |
| i | 52 | 58 | |
| j | 51.1 | 63 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.1 | 39.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 97.2 | 111.7 | |
| i | 55 | 62 | |
| j | 52.7 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 107 |
| b | 100 | |
| c | 86 | |
| d | 78 | |
| e | 6 | |
| f | 55 | |
| g | 12 | |
| g1 | 2 | |
| h | 113 | |
| i | 89 | |
| j | 80 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 107 |
| b | 100 | |
| c | 86 | |
| d | 78 | |
| e | 6 | |
| f | 55 | |
| g | 12 | |
| g1 | 2 | |
| h | 113 | |
| i | 89 | |
| j | 80 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a | 107 |
| b | 100 | |
| c | 86 | |
| d | 78 | |
| e | 6 | |
| f | 55 | |
| g | 12 | |
| g1 | 2 | |
| h | 113 | |
| i | 89 | |
| j | 80 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a | 107 |
| b | 100 | |
| c | 86 | |
| d | 78 | |
| e | 6 | |
| f | 55 | |
| g | 12 | |
| g1 | 2 | |
| h | 113 | |
| i | 89 | |
| j | 80 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.8 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 79.6 | 107.7 | |
| i | 45 | 58 | |
| j | 54.8 | 66.3 | |
| k | 71.7 | 95.5 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.8 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 79.6 | 107.7 | |
| i | 45 | 58 | |
| j | 54.8 | 66.3 | |
| k | 71.7 | 95.5 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 32.2 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 85.3 | 107.7 | |
| i | 52 | 58 | |
| j | 54.6 | 66.3 | |
| k | 80.6 | 95.5 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 32.2 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 92.9 | 106 | |
| i | 55 | 62 | |
| j | 58.5 | 67.9 | |
| k | 89 | 102 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Choosing a Waterproof Industrial Plug for wet and dusty work environments is usually not a one-step decision. In real pr...
READ MORE
Upgrading industrial electrical setups often involves considering new socket configurations. Incorporating a Wall Mounte...
READ MORE
A Wall Mounted Industrial Socket and a 240V Industrial Socket are used in workshops, factories, and big work areas. They...
READ MORE
When working with industrial electrical setups, understanding the proper care of a Wall Mounted Industrial Socket and a ...
READ MOREPanel connectors live in the real world: vibration, tight cabinet space, hurried maintenance, and occasional "someone plugged the wrong thing in." A well-chosen Panel-Mounted Straight Socket reduces downtime by making connections mechanically correct, electrically compatible, and easy to service from the front of an enclosure. Below is a practical checklist used by many OEM builders and plant electricians when specifying panel sockets.
Start with the application: where the socket is mounted
Panel-mounted sockets are typically installed on:
A straight panel format is often preferred when you want predictable cable routing inside the enclosure and a tidy external interface.
Electrical matching: current, voltage, and pole count
Choosing the right rating is more than compliance—it's reliability under load.
Then confirm the conductor needs:
Selecting the wrong pole layout is one of the fastest ways to create wiring compromises inside a cabinet (and nobody enjoys those).
4h vs 6h earth position: the built-in "wrong-plug prevention"
The 4h/6h earth contact position is a mechanical keying method widely used to reduce mismating between systems.
Standardizing 6h for general use and reserving 4h for specific supplies can simplify training and reduce errors during maintenance.
IP rating and environment: choose protection that matches reality
For panel interfaces exposed to dust, humidity, or washdown practices, IP rating matters.
In practice, the right IP level helps prevent corrosion on contacts and avoids intermittent faults that are painful to diagnose.
Installation fit: dimensions and cable cross-section
Panel products succeed or fail on mechanics:
If your wiring team uses multiple cable sizes, "large cable entry" variants can reduce SKU complexity
Why "Blue" matters: faster identification and safer maintenance
Color coding isn't just branding. A Blue Industrial Socket on a panel can:
A dependable Panel-Mounted Straight Socket is chosen by matching current + poles + voltage, confirming 4h/6h keying, and selecting an IP rating that reflects the environment—not the brochure. Add consistent color coding such as a Blue Industrial Socket option, and your cabinets become easier to service, harder to misuse, and simpler to standardize across projects.