An industrial socket on an outside wall faces rain, dust, sun, and cold. It sits there, sometimes for months, waiting fo...
READ MORE
Beautiful in appeara nce, easy installation, complete specifications, safety and reliable, It's applicable for special, waterproof,dustproofand corrosion-proof location.
Standard: IEC60529,EN60309
Degree of Protection: IP66
| Circuit Way | Wall Mounted | ||
| L(mm) | W(mm) | H(mm) | |
| 6way | 165 | 200 | 100 |
| 9way | 219 | 200 | 100 |
| 12way | 273 | 230 | 110 |
| 18way | 381 | 230 | 110 |
| 24way | 273 | 380 | 110 |
| 36way | 381 | 380 | 110 |
Waterproof, dustprrof, corrosion resistance, high strength insulation.
Opening hole according to user requirements, specifications, eass ofinstallation.
Optional flame retardant ABS or PC material plastic.
Standard: IEC60529, EN60309.
Degree of Protection: IP65.
| L(mm) | W(mm) | H(mm) |
| 110 | 80 | 70 |
| 130 | 80 | 70 |
| 180 | 80 | 70 |
| 250 | 80 | 70 |
| 100 | 100 | 75 |
| 125 | 125 | 75 |
| 200 | 150 | 100 |
| 250 | 150 | 100 |
| 340 | 220 | 150 |
| 400 | 300 | 160 |
| 460 | 270 | 160 |
| 520 | 300 | 160 |
| 540 | 360 | 180 |

| Dimension Specification |
L | W | H | Hole | IP |
| SF 50×50 | 50 | 50 | 4 | 55 | |
| SF 80×50 | 80 | 50 | 4 | 55 | |
| SF 85×85×50 | 85 | 85 | 50 | 7 | 55 |
| SF 100×100×70 | 100 | 100 | 70 | 7 | 65 |
| SF 150×110×70 | 150 | 110 | 70 | 10 | 65 |
| SF 150×150×70 | 150 | 150 | 70 | 8 | 65 |
| SF 200×100×70 | 200 | 155 | 80 | 8 | 65 |
| SF 200×155×80 | 200 | 100 | 70 | 10 | 65 |
| SF 225×200×80 | 255 | 200 | 80 | 12 | 65 |
| SF 300×250×120 | 300 | 250 | 120 | 12 | 65 |
| SF 400×350×120 | 400 | 350 | 120 | 16 | 65 |
Material:Made from UL Nylon 66,94V-2 and tight ring from rubber.
Feature:1.Special designation,good strengthsileand none damage to electrical machine.
2.Not need to disorganization the fix terminal,cable can be inserted through directly then tighten easy and save time.
Application:Used for machinery control box,distribution plate,machine and electrical.Etc.
| Type | Thread length L1 | Entry range D1 | Entry thread D2 | Cable gland dimensions L-L1 | Locknut thread size D3 |
| PG-07 | 8 | 3.5-3.6 | 23-8 | 16.5 | |
| PG-09 | 8 | 4.5-7 | 10.2 | 25-8 | 21.5 |
| PG-11 | 8 | 5.5-10 | 11.5 | 27-8 | 25 |
| PG-13.5 | 9 | 9-13 | 13.5 | 28-9 | 27 |
| PG-16 | 10 | 10-14 | 16.5 | 30-10 | 30 |
| PG-19 | 10 | 14-18 | 30 | 10-12 | 28 |
| PG-21 | 11 | 4-18 | 21 | 38-11 | 37.5 |
| PG-25 | 11 | 18-25 | 25 | 13-18 | 36 |
| PG-29 | 11 | 18-25 | 27.5 | 42-11 | 47.5 |
| PG-36 | 12 | 25-33 | 34.5 | 43-12 | 58 |
| PG-42 | 13 | 30-38 | 40.5 | 48-13 | 65 |
| PG-48 | 14 | 37-44 | 45.5 | 48-14 | 70 |
| PG-63 | 27 | 42-50 | 60 | 13-18 | 36 |
| Type | Threaded entry metric | Cable rangeΦ | Thread o.d.c1 | Panel mounting hole | Thread length C2 | Sealing nutsize F | Locknut size A |
| MG-12 | M12×1.25 | 7.6-4.6 | 12 | 12.5 | 8.5 | 19 | 18 |
| MG-14 | M14×1.25 | 7.6-4.6 | 14 | 14.5 | 8.5 | 20 | 19 |
| MG-16 | M16×1.5 | 10-6 | 16 | 16.5 | 15 | 22 | 22 |
| MG-18 | M18×1.5 | 10-6 | 18 | 18.5 | 15 | 25 | 22 |
| MG-20 | M20×1.5 | 14-9 | 20 | 20.5 | 15 | 27 | 27 |
| MG-24 | M24×1.5 | 14-9 | 24 | 24.5 | 15 | 33 | 27 |
| MG-25 | M25×1.5 | 18-13 | 25 | 25.5 | 15 | 33 | 33 |
| MG-27 | M27×1.5 | 18-13 | 27 | 27.5 | 15 | 35 | 35 |
| MG-32 | M32×1.5 | 25-18 | 32 | 33 | 15 | 41 | 41 |
| MG-36 | M36×1.5 | 25-18 | 36 | 36.5 | 20 | 45 | 41 |
| MG-40 | M40×1.5 | 30-24 | 40 | 41 | 20 | 50 | 50 |
| MG-50 | M50×1.5 | 39-30 | 50 | 51 | 22 | 62 | 61 |
| MG-63 | M63×1.5 | 48.5-40 | 63 | 64 | 25 | 75 | 75 |
| Model | Size(mm) | Cover Type |
| SF-2 | 579831 | Transparent |
| SF-3 | 759831 | Transparent |
| SF-4 | 939831 | Transparent |
| SF-6 | 107124.5(18686(window)) | Transparent |
| SF-8 | 1209831 | Transparent |
| SF-10 | 1699831 | Transparent |
| SF-12 | 2379831 | Transparent |
| SF-13 | 2559831 | Transparent |
| SF-16 | 3099831 | Transparent |
| SF-18 | 3459831 | Transparent |
An industrial socket on an outside wall faces rain, dust, sun, and cold. It sits there, sometimes for months, waiting fo...
READ MORE
Industrial power is not always clean or stable. Voltage varies by building, by generator, by line. A wide range strong v...
READ MORE
A low-voltage industrial plug carries 24V, 48V, or 110V into equipment, control panels, and tool connections. The voltag...
READ MORE
Two hundred amps is not a load you cycle on and off. It runs continuously. Generator output panels. Temporary power dist...
READ MORE