Sixty-three amps is not a light load. That current runs distribution boards, stage lighting rigs, construction site tran...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 129 | 159 |
| b | 76 | 92 | |
| c | 6-15 | 10-20 | |
| sw | 38 | 50 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 129 | 159 |
| b | 76 | 92 | |
| c | 6-15 | 10-20 | |
| sw | 38 | 50 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 135 | 159 |
| b | 80 | 92 | |
| c | 6-15 | 10-20 | |
| sw | 38 | 50 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 142 | 165 |
| b | 89 | 98 | |
| c | 8-16 | 10-20 | |
| sw | 42 | 50 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 162 |
| b | 78 | 96 | |
| c | 6-15 | 10-20 | |
| sw | 38 | 50 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 162 |
| b | 78 | 96 | |
| c | 6-15 | 10-20 | |
| sw | 38 | 50 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 139 | 162 |
| b | 84 | 96 | |
| c | 6-15 | 10-20 | |
| sw | 38 | 50 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 145 | 168 |
| b | 92 | 102 | |
| c | 8-16 | 12-22 | |
| sw | 42 | 50 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 261 | 305 |
| b | 114 | 115 | |
| c | 30 | 44.5 | |
| d | 112 | 130 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 16A, 125A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 261 | 305 |
| b | 114 | 115 | |
| c | 30 | 44.5 | |
| d | 112 | 130 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 261 | 305 |
| b | 114 | 115 | |
| c | 30 | 44.5 | |
| d | 112 | 130 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 261 | 305 |
| b | 114 | 115 | |
| c | 30 | 44.5 | |
| d | 112 | 130 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Sixty-three amps is not a light load. That current runs distribution boards, stage lighting rigs, construction site tran...
READ MORE
Factories run on electricity. Data centers. Construction sites. Shipyards. Event stages. Anywhere heavy equipment plugs ...
READ MORE
Electrical outlets in harsh environments need more than just a cover. Rain, dust, pressure washing, humidity—exposure ki...
READ MORE
At 200 amps, you are feeding a distribution board, a generator tap box, or a temporary power setup for an entire site se...
READ MORE