A control panel needs a 24V socket for a test light. A packaging line needs a 48V connection for a sensor. A workshop be...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 133 | 143 |
| b | 81 | 81 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 193 | 223 |
| b | 123 | 145 | |
| c | 153 | 185 | |
| d | 111 | 123 | |
| e | 21 | 17 | |
| f | 6 | 8 | |
| g | 288 | 317 | |
| h | 127 | 140 | |
| PG | 29 | 36 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 193 | 223 |
| b | 123 | 145 | |
| c | 153 | 185 | |
| d | 111 | 123 | |
| e | 21 | 17 | |
| f | 6 | 8 | |
| g | 288 | 317 | |
| h | 127 | 140 | |
| PG | 29 | 36 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 193 | 223 |
| b | 123 | 145 | |
| c | 153 | 185 | |
| d | 111 | 133 | |
| e | 21 | 17 | |
| f | 6 | 8 | |
| g | 288 | 317 | |
| h | 127 | 140 | |
| PG | 29 | 36 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

A control panel needs a 24V socket for a test light. A packaging line needs a 48V connection for a sensor. A workshop be...
READ MORE
An industrial socket on an outside wall faces rain, dust, sun, and cold. It sits there, sometimes for months, waiting fo...
READ MORE
Industrial power is not always clean or stable. Voltage varies by building, by generator, by line. A wide range strong v...
READ MORE
A low-voltage industrial plug carries 24V, 48V, or 110V into equipment, control panels, and tool connections. The voltag...
READ MOREElectrical problems on tractors and implements rarely start in the cable—they start at the connector interface. A correctly selected Industrial Implement Socket protects power delivery and reduces intermittent faults caused by rough terrain, contamination, and repeated connect/disconnect cycles.
Where Implement Sockets Are Used (Typical Circuits)
Industrial implement sockets commonly support:
Stable contact pressure and solid termination matter more here than "extra features" that don't survive field abuse.
The Most Common Causes of Socket Trouble
Failures typically come from a few predictable sources:
A rugged socket design plus correct installation prevents most of these issues.
Selection Checklist (Buyer-Friendly)
Before choosing an Industrial Implement Socket, confirm:
A well-built Industrial Implement Socket may look like a minor component, but it often determines whether field equipment stays productive or sits idle with an intermittent fault. When you align electrical rating, mounting method, and sealing level with real working conditions—vibration, mud, washdown, and temperature swings—lighting and auxiliary power remain steady season after season. At WENZHOU SHANGFENG ELECTRIC CO., LTD, we focus on dependable implement-socket solutions that help reduce connection-related downtime in agricultural and off-road applications.