Factories run on electricity. Data centers. Construction sites. Shipyards. Event stages. Anywhere heavy equipment plugs ...
READ MORE
| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 26 | 30 | |
| f | 42 | 50 | |
| g | 5 | 5 | |
| h | 55 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 64 | 73 | |
| e | 74 | 98 | |
| f | 40 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 64 | 73 | |
| e | 74 | 98 | |
| f | 40 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 65 | 73 | |
| e | 83 | 98 | |
| f | 48 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 65 | 73 | |
| e | 90 | 103 | |
| f | 53 | 61 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 134 | 148 |
| b | 80 | 88 | |
| c | 71 | 71 | |
| d | 43.5 | 57.5 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 32.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

Factories run on electricity. Data centers. Construction sites. Shipyards. Event stages. Anywhere heavy equipment plugs ...
READ MORE
Electrical outlets in harsh environments need more than just a cover. Rain, dust, pressure washing, humidity—exposure ki...
READ MORE
At 200 amps, you are feeding a distribution board, a generator tap box, or a temporary power setup for an entire site se...
READ MORE
An industrial socket without an interlock is just a live hole. A mechanical interlocking socket adds a physical gate. Th...
READ MOREElectrical problems on tractors and implements rarely start in the cable—they start at the connector interface. A correctly selected Industrial Implement Socket protects power delivery and reduces intermittent faults caused by rough terrain, contamination, and repeated connect/disconnect cycles.
Where Implement Sockets Are Used (Typical Circuits)
Industrial implement sockets commonly support:
Stable contact pressure and solid termination matter more here than "extra features" that don't survive field abuse.
The Most Common Causes of Socket Trouble
Failures typically come from a few predictable sources:
A rugged socket design plus correct installation prevents most of these issues.
Selection Checklist (Buyer-Friendly)
Before choosing an Industrial Implement Socket, confirm:
A well-built Industrial Implement Socket may look like a minor component, but it often determines whether field equipment stays productive or sits idle with an intermittent fault. When you align electrical rating, mounting method, and sealing level with real working conditions—vibration, mud, washdown, and temperature swings—lighting and auxiliary power remain steady season after season. At WENZHOU SHANGFENG ELECTRIC CO., LTD, we focus on dependable implement-socket solutions that help reduce connection-related downtime in agricultural and off-road applications.