Hard work places put a lot of pressure on electrical systems. This is true for mines, factories, shipyards, and outdoor ...
READ MORE
| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 134 | 148 |
| b | 80 | 88 | |
| c | 71 | 71 | |
| d | 43.5 | 57.5 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 32.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 139 | 148.5 |
| b | 80 | 88 | |
| c | 71 | 71 | |
| d | 50 | 57 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 32.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 138.5 | 150.5 |
| b | 83 | 90 | |
| c | 71 | 71 | |
| d | 55 | 64 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 33.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 56 | 56 |
| b | 56 | 56 | |
| c | 70.5 | 70.5 | |
| d | 70.5 | 70.5 | |
| e | 45 | 57 | |
| f | 23 | 28 | |
| g | 42 | 51 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 56 | 56 |
| b | 56 | 56 | |
| c | 70.5 | 70.5 | |
| d | 70.5 | 70.5 | |
| e | 42 | 57 | |
| f | 23 | 28 | |
| g | 42 | 51 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 56 | 56 |
| b | 56 | 56 | |
| c | 70.5 | 70.5 | |
| d | 70.5 | 70.5 | |
| e | 57 | 63 | |
| f | 23 | 28 | |
| g | 42 | 51 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

Hard work places put a lot of pressure on electrical systems. This is true for mines, factories, shipyards, and outdoor ...
READ MORE
On temporary construction sites, workers need power fast. They need to move machines around. They also need to keep the ...
READ MORE
Outdoor power systems face a lot of trouble. They get wet. They get dusty. They shake a lot. The work conditions are not...
READ MORE
Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MOREElectrical problems on tractors and implements rarely start in the cable—they start at the connector interface. A correctly selected Industrial Implement Socket protects power delivery and reduces intermittent faults caused by rough terrain, contamination, and repeated connect/disconnect cycles.
Where Implement Sockets Are Used (Typical Circuits)
Industrial implement sockets commonly support:
Stable contact pressure and solid termination matter more here than "extra features" that don't survive field abuse.
The Most Common Causes of Socket Trouble
Failures typically come from a few predictable sources:
A rugged socket design plus correct installation prevents most of these issues.
Selection Checklist (Buyer-Friendly)
Before choosing an Industrial Implement Socket, confirm:
A well-built Industrial Implement Socket may look like a minor component, but it often determines whether field equipment stays productive or sits idle with an intermittent fault. When you align electrical rating, mounting method, and sealing level with real working conditions—vibration, mud, washdown, and temperature swings—lighting and auxiliary power remain steady season after season. At WENZHOU SHANGFENG ELECTRIC CO., LTD, we focus on dependable implement-socket solutions that help reduce connection-related downtime in agricultural and off-road applications.