Choosing a Waterproof Industrial Plug for wet and dusty work environments is usually not a one-step decision. In real pr...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 155 | 195.9 |
| b | 81 | 102.7 | |
| c | 51.1 | 64.2 | |
| d | 49.5 | 64.2 | |
| e | 86 | 101.8 | |
| f | 34.7 | 37 | |
| g | 57 | 71.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 155 | 195.9 |
| b | 81 | 102.7 | |
| c | 51.1 | 64.2 | |
| d | 49.5 | 64.2 | |
| e | 86 | 101.8 | |
| f | 34.7 | 37 | |
| g | 57 | 71.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 155 | 195.9 |
| b | 81 | 102.7 | |
| c | 51.2 | 64.2 | |
| d | 55.7 | 64.2 | |
| e | 90.4 | 101.8 | |
| f | 37 | 37 | |
| g | 61.2 | 71.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 160 | 195 |
| b | 86 | 103.2 | |
| c | 51 | 62.8 | |
| d | 63 | 70.8 | |
| e | 97.2 | 104.9 | |
| f | 37 | 37 | |
| g | 75.5 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 257 |
| b | 112.5 | |
| c | 85 | |
| d | 77.4 | |
| e | 108 | |
| f | 34 | |
| g | 92 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 257 |
| b | 112.5 | |
| c | 85 | |
| d | 77.4 | |
| e | 108 | |
| f | 34 | |
| g | 92 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a | 257 |
| b | 112.5 | |
| c | 85 | |
| d | 77.4 | |
| e | 108 | |
| f | 34 | |
| g | 92 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a | 257 |
| b | 112.5 | |
| c | 85 | |
| d | 77.4 | |
| e | 108 | |
| f | 34 | |
| g | 92 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 158.6 | 199.2 |
| b | 81 | 102.7 | |
| c | 54.7 | 67.5 | |
| d | 49.5 | 64.2 | |
| e | 71.7 | 95.5 | |
| f | 79.6 | 98.7 | |
| g | 34.7 | 37 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 158.6 | 199.2 |
| b | 81 | 102.7 | |
| c | 54.7 | 67.5 | |
| d | 49.5 | 64.2 | |
| e | 71.7 | 95.5 | |
| f | 79.6 | 98.7 | |
| g | 34.7 | 37 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 158.6 | 199.2 |
| b | 80.6 | 102.7 | |
| c | 54.9 | 67.5 | |
| d | 55.7 | 64.2 | |
| e | 80.6 | 95.5 | |
| f | 85.2 | 98.7 | |
| g | 37 | 37 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 142 | 200 |
| b | 119 | 103.2 | |
| c | 56 | 67.8 | |
| d | 63 | 70.8 | |
| e | 89 | 102 | |
| f | 92.8 | 104.9 | |
| g | 37 | 37 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Choosing a Waterproof Industrial Plug for wet and dusty work environments is usually not a one-step decision. In real pr...
READ MORE
Upgrading industrial electrical setups often involves considering new socket configurations. Incorporating a Wall Mounte...
READ MORE
A Wall Mounted Industrial Socket and a 240V Industrial Socket are used in workshops, factories, and big work areas. They...
READ MORE
When working with industrial electrical setups, understanding the proper care of a Wall Mounted Industrial Socket and a ...
READ MORE