Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MORE
| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 122 | 139 |
| b | 59 | 75 | |
| c | 51 | 64 | |
| Ø | 6 | 8 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 122 | 139 |
| b | 65 | 75 | |
| c | 55 | 64 | |
| Ø | 6 | 8 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 130 | 143 |
| b | 72 | 84 | |
| c | 64 | 70 | |
| Ø | 8 | 8 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 231.5 | 293 |
| b | 110 | 125 | |
| c | 16-38 | 30-50 | |
| Ø | 110 | 125 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 231.5 | 293 |
| b | 110 | 125 | |
| c | 16-38 | 30-50 | |
| Ø | 110 | 125 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 231.5 | 293 |
| b | 110 | 125 | |
| c | 16-38 | 30-50 | |
| Ø | 110 | 125 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A. 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 141 | 178 |
| b | 59 | 75 | |
| c | 51 | 64 | |
| Ø | 8 | 10 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 63A. 125A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 141 | 178 |
| b | 59 | 75 | |
| c | 51 | 64 | |
| Ø | 8 | 10 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 141 | 178 |
| b | 65 | 75 | |
| c | 55 | 64 | |
| Ø | 8 | 10 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 169 | 181 |
| b | 72 | 84 | |
| c | 64 | 70 | |
| Ø | 10 | 10 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 135 | 153 |
| b | 92 | 102 | |
| c | 71 | 71 | |
| d | 50 | 65 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 32.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 135 | 153 |
| b | 92 | 102 | |
| c | 71 | 71 | |
| d | 50 | 65 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 32.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MORE
Choosing a Waterproof Industrial Plug for wet and dusty work environments is usually not a one-step decision. In real pr...
READ MORE
Upgrading industrial electrical setups often involves considering new socket configurations. Incorporating a Wall Mounte...
READ MORE
A Wall Mounted Industrial Socket and a 240V Industrial Socket are used in workshops, factories, and big work areas. They...
READ MORE