Standard plugs handle 10, 15, maybe 30 amps. But industrial equipment needs more. Welders. Large compressors. Temporary ...
READ MORE
| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 54.5 | 68 | |
| f | 88 | 96 | |
| g | 114 | 129 | |
| h | 108 | 122 | |
| i | 75 | 90 | |
| Cable nominal cross-section area(mm²) | 6-25 | 25-70 | |
| Current(A): | 63A. 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 54.5 | 68 | |
| f | 88 | 96 | |
| g | 114 | 129 | |
| h | 108 | 122 | |
| i | 75 | 90 | |
| Cable nominal cross-section area(mm²) | 6-25 | 25-70 | |
| Current(A): | 63A. 125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 54.5 | 68 | |
| f | 88 | 96 | |
| g | 114 | 129 | |
| h | 108 | 122 | |
| i | 75 | 90 | |
| Cable nominal cross-section area(mm²) | 6-25 | 25-70 | |
| Current(A): | 63A. 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 73 | 87 |
| b | 70 | 91 | |
| c | 62 | 80 | |
| d | 54 | 73 | |
| e | 49 | 71 | |
| f | 33 | 42 | |
| g | 47 | 61 | |
| i | 36 | 44 | |
| j | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 73 | 87 |
| b | 70 | 91 | |
| c | 62 | 80 | |
| d | 54 | 73 | |
| e | 49 | 71 | |
| f | 33 | 42 | |
| g | 47 | 61 | |
| i | 36 | 44 | |
| j | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 80 | 87 |
| b | 78 | 91 | |
| c | 76 | 80 | |
| d | 61 | 73 | |
| e | 62 | 71 | |
| f | 42 | 42 | |
| g | 60 | 61 | |
| i | 44 | 44 | |
| j | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 79 | 87 |
| b | 86 | 94 | |
| c | 75 | 82 | |
| d | 68 | 72 | |
| e | 62 | 71 | |
| f | 37 | 43 | |
| g | 60 | 61 | |
| h | 68 | 80 | |
| i | 42 | 44 | |
| j | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 134 | 148 |
| b | 80 | 88 | |
| c | 71 | 71 | |
| d | 43.5 | 57.5 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 32.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 134 | 148 |
| b | 80 | 88 | |
| c | 71 | 71 | |
| d | 43.5 | 57.5 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 32.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 139 | 148.5 |
| b | 80 | 88 | |
| c | 71 | 71 | |
| d | 50 | 57 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 32.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 138.5 | 150.5 |
| b | 83 | 90 | |
| c | 71 | 71 | |
| d | 55 | 64 | |
| e | 57 | 57 | |
| f | 20 | 20 | |
| g | 32.5 | 33.5 | |
| h | 6.5 | 6.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 56 | 56 |
| b | 56 | 56 | |
| c | 70.5 | 70.5 | |
| d | 70.5 | 70.5 | |
| e | 45 | 57 | |
| f | 23 | 28 | |
| g | 42 | 51 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

Standard plugs handle 10, 15, maybe 30 amps. But industrial equipment needs more. Welders. Large compressors. Temporary ...
READ MORE
Single-phase power is everywhere. 230 volts. Enough for lights and computers. Industrial equipment needs more. Big motor...
READ MORE
Hard work places put a lot of pressure on electrical systems. This is true for mines, factories, shipyards, and outdoor ...
READ MORE
On temporary construction sites, workers need power fast. They need to move machines around. They also need to keep the ...
READ MORE