Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MORE
| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 26 | 30 | |
| f | 42 | 50 | |
| g | 5 | 5 | |
| h | 55 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 64 | 73 | |
| e | 74 | 98 | |
| f | 40 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 64 | 73 | |
| e | 74 | 98 | |
| f | 40 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 65 | 73 | |
| e | 83 | 98 | |
| f | 48 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 65 | 73 | |
| e | 90 | 103 | |
| f | 53 | 61 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | |
| Rated current(A) | 200 | |
| Pole | 4 | |
| Dimension(mm) | a | 302 |
| b | 142 | |
| c | 134 | |
| d | 65 | |
| Ø | 45-66 | |
| Cable nominal cross-section area(mm²) | 45-66 | |
| Current(A): | 200A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MORE
Choosing a Waterproof Industrial Plug for wet and dusty work environments is usually not a one-step decision. In real pr...
READ MORE
Upgrading industrial electrical setups often involves considering new socket configurations. Incorporating a Wall Mounte...
READ MORE
A Wall Mounted Industrial Socket and a 240V Industrial Socket are used in workshops, factories, and big work areas. They...
READ MORE