Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | axb | 75 | 75 |
| cxd | 61 | 61 | |
| e | 22 | 24 | |
| f | 60 | 70 | |
| g | 5 | 5 | |
| h | 50 | 55 | |
| i | 87 | 95 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | axb | 75 | 75 |
| cxd | 61 | 61 | |
| e | 22 | 24 | |
| f | 60 | 70 | |
| g | 5 | 5 | |
| h | 50 | 55 | |
| i | 87 | 95 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | axb | 75 | 75 |
| cxd | 61 | 61 | |
| e | 17 | 24 | |
| f | 59 | 69 | |
| g | 5 | 5 | |
| h | 50 | 55 | |
| i | 88 | 95 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | axb | 75 | 75 |
| cxd | 61 | 61 | |
| e | 17 | 22 | |
| f | 59 | 71 | |
| g | 5 | 5 | |
| h | 55 | 60 | |
| i | 92 | 100 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 18 | 24 | |
| f | 63 | 70 | |
| g | 50 | 55 | |
| h | 50 | 55 | |
| i | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 18 | 24 | |
| f | 63 | 70 | |
| g | 50 | 55 | |
| h | 50 | 55 | |
| i | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 18 | 24 | |
| f | 63 | 70 | |
| g | 50 | 55 | |
| h | 50 | 55 | |
| i | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 18 | 24 | |
| f | 63 | 76 | |
| g | 55 | 60 | |
| h | 55 | 60 | |
| i | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 35 | 44 | |
| f | 96 | 106 | |
| g | 80 | 100 | |
| h | 80 | 100 | |
| i | 7 | 7 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A,125A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 35 | 44 | |
| f | 96 | 106 | |
| g | 80 | 100 | |
| h | 80 | 100 | |
| i | 7 | 7 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 35 | 44 | |
| f | 96 | 106 | |
| g | 80 | 100 | |
| h | 80 | 100 | |
| i | 7 | 7 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 35 | 44 | |
| f | 96 | 106 | |
| g | 80 | 100 | |
| h | 80 | 100 | |
| i | 7 | 7 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MORE
Choosing a Waterproof Industrial Plug for wet and dusty work environments is usually not a one-step decision. In real pr...
READ MORE
Upgrading industrial electrical setups often involves considering new socket configurations. Incorporating a Wall Mounte...
READ MORE
A Wall Mounted Industrial Socket and a 240V Industrial Socket are used in workshops, factories, and big work areas. They...
READ MORE