Electrical systems on construction sites deal with very tough conditions. These include dust, debris, constant vibration...
READ MOREEarth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 140 | 173 |
b | 116 | 144 | |
c | 43.5 | 57 | |
d | 38.5 | 51 | |
e | 17.5 | 25 | |
f | 47 | 62 | |
g | 58 | 80.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 140 | 173 |
b | 116 | 144 | |
c | 43.5 | 57 | |
d | 38.5 | 51 | |
e | 17.5 | 25 | |
f | 47 | 62 | |
g | 58 | 80.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 140 | 173 |
b | 116 | 144 | |
c | 49.5 | 57 | |
d | 43.5 | 51 | |
e | 21.5 | 25 | |
f | 52 | 62 | |
g | 66.7 | 80.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 144 | 173 |
b | 121 | 144 | |
c | 56 | 63.3 | |
d | 50 | 56.5 | |
e | 26.5 | 30.3 | |
f | 60 | 68.7 | |
g | 75 | 89 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Earth contact position | 4h | |
Rated current(A) | 63 | |
Pole | 3 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 3 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 4 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 5 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 220-380V~/240-415V~ 3P+N+E |
Protection degree: | IP44 |
Earth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 138 | 170 |
b | 115 | 141 | |
c | 24.7 | 32.5 | |
d | 70.2 | 93.3 | |
e | 38.3 | 51 | |
f | 17.5 | 25 | |
g | 47 | 62.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 138 | 170 |
b | 115 | 141 | |
c | 24.7 | 32.5 | |
d | 70.2 | 93.3 | |
e | 38.3 | 51 | |
f | 17.5 | 25 | |
g | 47 | 62.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 144 | 170 |
b | 120.5 | 141 | |
c | 25.2 | 32.5 | |
d | 78 | 93.3 | |
e | 43.8 | 51 | |
f | 21.5 | 25 | |
g | 52.2 | 62.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 144 | 177 |
b | 120.5 | 148 | |
c | 25.2 | 32.5 | |
d | 87 | 101 | |
e | 50.2 | 56.5 | |
f | 26.5 | 30.3 | |
g | 60 | 68.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP67 |
Electrical systems on construction sites deal with very tough conditions. These include dust, debris, constant vibration...
READ MOREIn places where a power supply is very important, the Industrial Socket Outlet and the 3-Pin Plug Socket are key parts. ...
READ MOREIn offices, electricity is very important. It is needed for every day work. It powers computers, printers, and phones. T...
READ MOREWhen we talk about power in workplaces, two important parts are the Industrial Socket Outlet and the 3-Pin Plug Socket. ...
READ MORE