| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 238.9 | 286 |
| b | 179.5 | 219 | |
| c | 51.1 | 57 | |
| d | 69.5 | 81.1 | |
| e | 113 | 131.5 | |
| f | 75.5 | 83.3 | |
| g | 36.5 | 42.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | 25-35 | |
| Current(A): | 63A,125A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 238.9 | 286 |
| b | 179.5 | 219 | |
| c | 51.1 | 57 | |
| d | 69.5 | 81.1 | |
| e | 113 | 131.5 | |
| f | 75.5 | 83.3 | |
| g | 36.5 | 42.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | 25-35 | |
| Current(A): | 16A,125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 238.9 | 286 |
| b | 179.5 | 219 | |
| c | 51.1 | 57 | |
| d | 69.5 | 81.1 | |
| e | 113 | 131.5 | |
| f | 75.5 | 83.3 | |
| g | 36.5 | 42.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | 25-35 | |
| Current(A): | 63A,125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 238.9 | 286 |
| b | 179.5 | 219 | |
| c | 51.1 | 57 | |
| d | 69.5 | 81.1 | |
| e | 113 | 131.5 | |
| f | 75.5 | 83.3 | |
| g | 36.5 | 42.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | 25-35 | |
| Current(A): | 63A,125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 25° | 25° |
| b | 127.9 | 156.4 | |
| c | 123.7 | 147.8 | |
| d | 94.6 | 120.7 | |
| e | 77.5 | 79 | |
| f | 88 | 98.5 | |
| g | 64.2 | 90.2 | |
| M | M25 | M32 | |
| M | A M25 plug cuttable | A M32 plug cuttable | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 25° | 25° |
| b | 127.9 | 156.4 | |
| c | 123.7 | 147.8 | |
| d | 94.6 | 120.7 | |
| e | 77.5 | 79 | |
| f | 88 | 98.5 | |
| g | 64.2 | 90.2 | |
| M | M25 | M32 | |
| M | A M25 plug cuttable | A M32 plug cuttable | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 25° | 25° |
| b | 129.9 | 156.4 | |
| c | 128.7 | 147.8 | |
| d | 94.6 | 120.7 | |
| e | 77.5 | 79 | |
| f | 88 | 98.5 | |
| g | 64.2 | 90.2 | |
| M | M25 | M32 | |
| M | A M25 plug cuttable | A M32 plug cuttable | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 25° | 25° |
| b | 135.4 | 158 | |
| c | 128.8 | 157.2 | |
| d | 94.6 | 120.7 | |
| e | 77.5 | 79 | |
| f | 88 | 98.5 | |
| g | 64.2 | 90.2 | |
| M | M25 | M32 | |
| M | A M25 plug cuttable | A M32 plug cuttable | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 25° |
| b | 216 | |
| c | 165 | |
| d | 171 | |
| e | 108 | |
| f | 136 | |
| g | 133 | |
| M | M40 | |
| M | A M40 plug cuttable | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 25° |
| b | 216 | |
| c | 165 | |
| d | 171 | |
| e | 108 | |
| f | 136 | |
| g | 133 | |
| M | M40 | |
| M | A M40 plug cuttable | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a | 25° |
| b | 216 | |
| c | 165 | |
| d | 171 | |
| e | 108 | |
| f | 136 | |
| g | 133 | |
| M | M40 | |
| M | A M40 plug cuttable | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a | 25° |
| b | 216 | |
| c | 165 | |
| d | 171 | |
| e | 108 | |
| f | 136 | |
| g | 133 | |
| M | M40 | |
| M | A M40 plug cuttable | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

Field engineers who work with temporary power stations, battery trailers, and movable energy units need wiring systems t...
READ MORE
Choosing a Waterproof Industrial Plug for wet and dusty work environments is usually not a one-step decision. In real pr...
READ MORE
Upgrading industrial electrical setups often involves considering new socket configurations. Incorporating a Wall Mounte...
READ MORE
A Wall Mounted Industrial Socket and a 240V Industrial Socket are used in workshops, factories, and big work areas. They...
READ MORE