An industrial socket on an outside wall faces rain, dust, sun, and cold. It sits there, sometimes for months, waiting fo...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 101 | 120 |
| b | 113 | 131 | |
| c | 80 | 100 | |
| d | 89 | 108 | |
| e | 64 | 87 | |
| f | 83 | 82 | |
| g | 87 | 105 | |
| h | 87 | 105 | |
| i | 7 | 7.5 | |
| Cable nominal cross-section area(mm²) | 6-25 | 16-25 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 101 | 120 |
| b | 113 | 131 | |
| c | 80 | 100 | |
| d | 89 | 108 | |
| e | 64 | 87 | |
| f | 83 | 82 | |
| g | 87 | 105 | |
| h | 87 | 105 | |
| i | 7 | 7.5 | |
| Cable nominal cross-section area(mm²) | 6-25 | 16-25 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 101 | 120 |
| b | 113 | 131 | |
| c | 80 | 100 | |
| d | 89 | 108 | |
| e | 64 | 87 | |
| f | 83 | 82 | |
| g | 87 | 105 | |
| h | 87 | 105 | |
| i | 7 | 7.5 | |
| Cable nominal cross-section area(mm²) | 6-25 | 16-25 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |
| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 101 | 120 |
| b | 113 | 131 | |
| c | 80 | 100 | |
| d | 89 | 108 | |
| e | 64 | 87 | |
| f | 83 | 82 | |
| g | 87 | 105 | |
| h | 87 | 105 | |
| i | 7 | 7.5 | |
| Cable nominal cross-section area(mm²) | 6-25 | 16-25 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 73 | 87 |
| b | 70 | 91 | |
| c | 62 | 80 | |
| d | 54 | 73 | |
| e | 49 | 71 | |
| f | 33 | 42 | |
| g | 47 | 61 | |
| i | 36 | 44 | |
| j | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 73 | 87 |
| b | 70 | 91 | |
| c | 62 | 80 | |
| d | 54 | 73 | |
| e | 49 | 71 | |
| f | 33 | 42 | |
| g | 47 | 61 | |
| i | 36 | 44 | |
| j | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 80 | 87 |
| b | 78 | 91 | |
| c | 76 | 80 | |
| d | 61 | 73 | |
| e | 62 | 71 | |
| f | 42 | 42 | |
| g | 60 | 61 | |
| i | 44 | 44 | |
| j | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 79 | 87 |
| b | 86 | 94 | |
| c | 75 | 82 | |
| d | 68 | 72 | |
| e | 62 | 71 | |
| f | 37 | 43 | |
| g | 60 | 61 | |
| h | 68 | 80 | |
| i | 42 | 44 | |
| j | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

An industrial socket on an outside wall faces rain, dust, sun, and cold. It sits there, sometimes for months, waiting fo...
READ MORE
Industrial power is not always clean or stable. Voltage varies by building, by generator, by line. A wide range strong v...
READ MORE
A low-voltage industrial plug carries 24V, 48V, or 110V into equipment, control panels, and tool connections. The voltag...
READ MORE
Two hundred amps is not a load you cycle on and off. It runs continuously. Generator output panels. Temporary power dist...
READ MOREStraight panel outlets are fine on roomy enclosures. In compact control cabinets, crowded distribution panels, or skid-mounted systems, however, the space behind the door disappears quickly. A Panel Mounted Angle Socket solves a very practical problem: it redirects the cable exit so conductors don't have to fight the enclosure, making wiring neater, closure easier, and maintenance less frustrating over the life of the equipment.
1) More clearance where it matters most: behind the panel
Angled outlets help installers route cables without pushing them into sharp bends.
For production builds, that often translates into quicker wiring and fewer "open it back up" corrections.
2) A cleaner front face—and fewer knocks in busy work zones
Industrial panels live in places where cables get dragged, bumped, and snagged.
Small geometry changes can make day-to-day handling noticeably smoother.
3) Low-voltage certified and multi-voltage options: useful for standard platforms
Many builders reuse one enclosure concept across multiple projects or regions. Choosing a Panel Mounted Angle Socket family that includes certified low-voltage versions and multi-voltage selections can help you:
That kind of planning reduces SKU sprawl and keeps field support simpler.
4) Pre-spec checks that prevent fitment surprises
Before finalizing a part number, a quick design review avoids the common headaches:
These checks cost minutes on paper and save hours in rework.
A Panel Mounted Angle Socket is a straightforward upgrade that improves rear clearance, protects cables from unnecessary strain, and makes panels easier to assemble and service—especially in compact or high-density builds. For manufacturers aiming to keep one cabinet design compatible across different voltage needs, angled panel-mounted sockets also support cleaner standardization and smoother long-term maintenance. For dependable production supply and consistent industrial connector solutions, partner with WENZHOU SHANGFENG ELECTRIC CO., LTD.