Big electrical systems need more than just big transformers and switchgear. They also need good connection parts like In...
READ MORE
| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 25° |
| b | 216 | |
| c | 169 | |
| d | 171 | |
| e | 108 | |
| f | 136 | |
| g | 133 | |
| M | M40 | |
| M | A M40 plug cuttable | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A,125A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 25° | 25° |
| b | 216 | 313 | |
| c | 169 | 203 | |
| d | 171 | 264 | |
| e | 108 | 140 | |
| f | 136 | 163 | |
| g | 133 | 240 | |
| M | M40 | M50 | |
| M | A M40 plug cuttable | A M50 plug cuttable | |
| Cable nominal cross-section area(mm²) | 10-16 | 25-35 | |
| Current(A): | 63A,125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 25° | 25° |
| b | 216 | 313 | |
| c | 169 | 203 | |
| d | 171 | 264 | |
| e | 108 | 140 | |
| f | 136 | 163 | |
| g | 133 | 240 | |
| M | M40 | M50 | |
| M | A M40 plug cuttable | A M50 plug cuttable | |
| Cable nominal cross-section area(mm²) | 10-16 | 25-35 | |
| Current(A): | 63A,125A |
| Voltage(V): | 380-410V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 25° | 25° |
| b | 216 | 313 | |
| c | 169 | 203 | |
| d | 171 | 264 | |
| e | 108 | 140 | |
| f | 136 | 163 | |
| g | 133 | 240 | |
| M | M40 | M50 | |
| M | A M40 plug cuttable | A M50 plug cuttable | |
| Cable nominal cross-section area(mm²) | 10-16 | 25-35 | |
| Current(A): | 63A,125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 155 | 195.9 |
| b | 81 | 102.7 | |
| c | 51.1 | 64.2 | |
| d | 49.5 | 64.2 | |
| e | 86 | 101.8 | |
| f | 34.7 | 37 | |
| g | 57 | 71.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 155 | 195.9 |
| b | 81 | 102.7 | |
| c | 51.1 | 64.2 | |
| d | 49.5 | 64.2 | |
| e | 86 | 101.8 | |
| f | 34.7 | 37 | |
| g | 57 | 71.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 155 | 195.9 |
| b | 81 | 102.7 | |
| c | 51.2 | 64.2 | |
| d | 55.7 | 64.2 | |
| e | 90.4 | 101.8 | |
| f | 37 | 37 | |
| g | 61.2 | 71.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 160 | 195 |
| b | 86 | 103.2 | |
| c | 51 | 62.8 | |
| d | 63 | 70.8 | |
| e | 97.2 | 104.9 | |
| f | 37 | 37 | |
| g | 75.5 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 257 |
| b | 112.5 | |
| c | 85 | |
| d | 77.4 | |
| e | 108 | |
| f | 34 | |
| g | 92 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 257 |
| b | 112.5 | |
| c | 85 | |
| d | 77.4 | |
| e | 108 | |
| f | 34 | |
| g | 92 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a | 257 |
| b | 112.5 | |
| c | 85 | |
| d | 77.4 | |
| e | 108 | |
| f | 34 | |
| g | 92 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a | 257 |
| b | 112.5 | |
| c | 85 | |
| d | 77.4 | |
| e | 108 | |
| f | 34 | |
| g | 92 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

Big electrical systems need more than just big transformers and switchgear. They also need good connection parts like In...
READ MORE
Production layouts change more frequently than before. Manufacturing lines are adjusted to accommodate new orders, tempo...
READ MORE
More and more places these days are using their own local power systems. Things like business parks, university campuses...
READ MORE
Small hardware decisions can ripple through a facility’s daily rhythm. Fixing power feed points where equipment routinel...
READ MOREOn paper, an industrial socket is just a connection point. On a real site—wet floors, airborne dust, constant plug changes—the wrong choice shows up fast: loose connections, damaged housings, or maintenance callouts that shouldn't have happened. A practical selection process starts with how the socket will be installed, then checks environmental protection and standards compliance, especially for projects that move across regions.
1) Match the Socket Style to the Installation
Different installations create different failure risks, so the mounting style is more than a cosmetic choice.
For temporary boards and outdoor distribution, the best option is usually the one that keeps the connection protected and easy to handle—not simply the one that fits the cutout.
2) Outdoor Applications: Focus on Sealing and Abuse, Not Just "Waterproof"
Choosing an Outdoor Industrial Socket is mostly about what the site will do to it:
Materials such as Nylon PA66 are popular in industrial enclosures for good reason: they handle impact, heat, and long-term wear better than lighter-duty plastics in many everyday field conditions.
3) Standards: Why IEC/EN 60309 Keeps Procurement Simple
If your equipment is shared across contractors or sourced internationally, standards alignment reduces mismatch risk and simplifies spares. Sockets designed around IEC60309 / EN60309 (CEE17) expectations generally support consistent mating and identification practices used across many industrial markets. For projects that require China domestic documentation, compliance with GB11918 / GB11919 can also be important for acceptance and audits.
4) Customization: What Buyers Commonly Specify (and Why)
A reliable Industrial Socket Supplier is often judged by how well they support real installation constraints, not just catalog models. Typical project requests include:
As an Industrial Socket Factory, SFE (WENZHOU SHANGFENG ELECTRIC CO., LTD) supports product customization based on customer parameters and application requirements—helping OEMs and contractors keep socket selection consistent across sites while meeting harsh-environment demands.