Big electrical systems need more than just big transformers and switchgear. They also need good connection parts like In...
READ MORE
| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 26 | 30 | |
| f | 42 | 50 | |
| g | 5 | 5 | |
| h | 55 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 64 | 73 | |
| e | 74 | 98 | |
| f | 40 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 64 | 73 | |
| e | 74 | 98 | |
| f | 40 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 65 | 73 | |
| e | 83 | 98 | |
| f | 48 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 65 | 73 | |
| e | 90 | 103 | |
| f | 53 | 61 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Big electrical systems need more than just big transformers and switchgear. They also need good connection parts like In...
READ MORE
Production layouts change more frequently than before. Manufacturing lines are adjusted to accommodate new orders, tempo...
READ MORE
More and more places these days are using their own local power systems. Things like business parks, university campuses...
READ MORE
Small hardware decisions can ripple through a facility’s daily rhythm. Fixing power feed points where equipment routinel...
READ MOREChoosing a Second Generation Industrial Implement Socket isn't about adding complexity—it's about improving reliability where equipment takes the most abuse: at the connection point. In agriculture and off‑road applications, the goal is simple: consistent power and signals despite vibration, contamination, and repetitive connect/disconnect cycles.
What Makes Second-Generation Sockets Worth Specifying
Second-generation designs typically focus on practical upgrades that reduce common field failures:
Typical Use Cases (Where the Upgrade Pays Off)
A Second Generation Industrial Implement Socket is commonly specified for:
Spec Checklist: How to Avoid Downtime from the Start
Before selecting a socket, verify these points (the boring checks that prevent expensive service calls):
The right Second Generation Industrial Implement Socket helps keep lighting, auxiliary power, and implement functions consistent when conditions are harsh and schedules are tight. Specify for the real environment—vibration, contamination, and frequent coupling—and you'll reduce intermittent faults that quietly drain uptime.