Standard plugs handle 10, 15, maybe 30 amps. But industrial equipment needs more. Welders. Large compressors. Temporary ...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 240 | 295 |
| b | 115 | 126 | |
| c | 30 | 44.5 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 240 | 295 |
| b | 115 | 126 | |
| c | 30 | 44.5 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 240 | 295 |
| b | 115 | 126 | |
| c | 30 | 44.5 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 240 | 295 |
| b | 115 | 126 | |
| c | 30 | 44.5 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 122 | 139 |
| b | 59 | 75 | |
| c | 51 | 64 | |
| Ø | 6 | 8 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 122 | 139 |
| b | 59 | 75 | |
| c | 51 | 64 | |
| Ø | 6 | 8 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 122 | 139 |
| b | 65 | 75 | |
| c | 55 | 64 | |
| Ø | 6 | 8 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 130 | 143 |
| b | 72 | 84 | |
| c | 64 | 70 | |
| Ø | 8 | 8 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 231.5 | 293 |
| b | 110 | 125 | |
| c | 16-38 | 30-50 | |
| Ø | 110 | 125 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 231.5 | 293 |
| b | 110 | 125 | |
| c | 16-38 | 30-50 | |
| Ø | 110 | 125 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 16A. 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 231.5 | 293 |
| b | 110 | 125 | |
| c | 16-38 | 30-50 | |
| Ø | 110 | 125 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A. 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 141 | 178 |
| b | 59 | 75 | |
| c | 51 | 64 | |
| Ø | 8 | 10 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 63A. 125A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

Standard plugs handle 10, 15, maybe 30 amps. But industrial equipment needs more. Welders. Large compressors. Temporary ...
READ MORE
Single-phase power is everywhere. 230 volts. Enough for lights and computers. Industrial equipment needs more. Big motor...
READ MORE
Hard work places put a lot of pressure on electrical systems. This is true for mines, factories, shipyards, and outdoor ...
READ MORE
On temporary construction sites, workers need power fast. They need to move machines around. They also need to keep the ...
READ MORESelecting Industrial Plugs isn't only about amperage and voltage; the connector layout affects safety, compatibility, and how smoothly a site runs. Below is a field-focused guide to the most common configurations and where they fit.
3‑phase power: where it shines
A 3 Phase Industrial Plug is widely used for motors, pumps, compressors, and heavy machinery because it supports efficient power delivery and steady operation under load. In many facilities, choosing a proper 3‑phase connector reduces nuisance trips and overheating caused by under‑spec'd connections.
4‑pin vs. 5‑pin: the key difference
Environmental durability matters as much as wiring
In wet, dusty, or high‑traffic environments, stable contact performance depends on more than the metal pins. Nylon PA66 housings support mechanical strength and long-term fit, while water- and dust-resistant construction helps reduce contamination, corrosion, and connection failures—especially in outdoor work or wash-down areas.
Why this matters for modern installations (including LED systems)
As installations become more complex—such as large LED displays and supporting power/control hardware—connector reliability and clear on-site identification become critical. A well-matched plug type helps prevent misconnection, speeds maintenance, and improves overall operational safety.