A Wall Mounted Industrial Socket and a 240V Industrial Socket are used in workshops, factories, and big work areas. They...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 140 | 173 |
| b | 116 | 144 | |
| c | 43.5 | 57 | |
| d | 38.5 | 51 | |
| e | 17.5 | 25 | |
| f | 47 | 62 | |
| g | 58 | 80.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 140 | 173 |
| b | 116 | 144 | |
| c | 43.5 | 57 | |
| d | 38.5 | 51 | |
| e | 17.5 | 25 | |
| f | 47 | 62 | |
| g | 58 | 80.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 140 | 173 |
| b | 116 | 144 | |
| c | 49.5 | 57 | |
| d | 43.5 | 51 | |
| e | 21.5 | 25 | |
| f | 52 | 62 | |
| g | 66.7 | 80.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 144 | 173 |
| b | 121 | 144 | |
| c | 56 | 63.3 | |
| d | 50 | 56.5 | |
| e | 26.5 | 30.3 | |
| f | 60 | 68.7 | |
| g | 75 | 89 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~ 3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 138 | 170 |
| b | 115 | 141 | |
| c | 24.7 | 32.5 | |
| d | 70.2 | 93.3 | |
| e | 38.3 | 51 | |
| f | 17.5 | 25 | |
| g | 47 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 138 | 170 |
| b | 115 | 141 | |
| c | 24.7 | 32.5 | |
| d | 70.2 | 93.3 | |
| e | 38.3 | 51 | |
| f | 17.5 | 25 | |
| g | 47 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 144 | 170 |
| b | 120.5 | 141 | |
| c | 25.2 | 32.5 | |
| d | 78 | 93.3 | |
| e | 43.8 | 51 | |
| f | 21.5 | 25 | |
| g | 52.2 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 144 | 177 |
| b | 120.5 | 148 | |
| c | 25.2 | 32.5 | |
| d | 87 | 101 | |
| e | 50.2 | 56.5 | |
| f | 26.5 | 30.3 | |
| g | 60 | 68.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

A Wall Mounted Industrial Socket and a 240V Industrial Socket are used in workshops, factories, and big work areas. They...
READ MORE
When working with industrial electrical setups, understanding the proper care of a Wall Mounted Industrial Socket and a ...
READ MORE
Wall Mounted Industrial Sockets and 240V Industrial Sockets are very common in workshops, factories, and big shops. Peop...
READ MORE
After a big storm, a flood, an earthquake, or a major power grid failure, getting electricity back up and running is one...
READ MORE