Construction sites are a fast-changing environment, where safety, reliability and efficiency are always key factors for ...
READ MOREEarth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 122 | 139 |
b | 59 | 75 | |
c | 51 | 64 | |
Ø | 6 | 8 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 122 | 139 |
b | 59 | 75 | |
c | 51 | 64 | |
Ø | 6 | 8 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 122 | 139 |
b | 65 | 75 | |
c | 55 | 64 | |
Ø | 6 | 8 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 130 | 143 |
b | 72 | 84 | |
c | 64 | 70 | |
Ø | 8 | 8 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 63 | 125 | |
Pole | 3 | ||
Dimension(mm) | a | 231.5 | 293 |
b | 110 | 125 | |
c | 16-38 | 30-50 | |
Ø | 110 | 125 | |
Cable nominal cross-section area(mm²) | 6-16 | 16-50 |
Current(A): | 16A. 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 63 | 125 | |
Pole | 4 | ||
Dimension(mm) | a | 231.5 | 293 |
b | 110 | 125 | |
c | 16-38 | 30-50 | |
Ø | 110 | 125 | |
Cable nominal cross-section area(mm²) | 6-16 | 16-50 |
Current(A): | 16A. 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 63 | 125 | |
Pole | 5 | ||
Dimension(mm) | a | 231.5 | 293 |
b | 110 | 125 | |
c | 16-38 | 30-50 | |
Ø | 110 | 125 | |
Cable nominal cross-section area(mm²) | 6-16 | 16-50 |
Current(A): | 63A. 125A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP67 |
Earth contact position | 4h | ||
Rated current(A) | 63 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 141 | 178 |
b | 59 | 75 | |
c | 51 | 64 | |
Ø | 8 | 10 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 63A. 125A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 141 | 178 |
b | 59 | 75 | |
c | 51 | 64 | |
Ø | 8 | 10 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 141 | 178 |
b | 65 | 75 | |
c | 55 | 64 | |
Ø | 8 | 10 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 169 | 181 |
b | 72 | 84 | |
c | 64 | 70 | |
Ø | 10 | 10 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Construction sites are a fast-changing environment, where safety, reliability and efficiency are always key factors for ...
READ MOREIndustrial power distribution systems require rugged plugs, high-current plugs and receptacles, and multi-receptacle con...
READ MOREWith the continuous development of automation technology, industrial equipment has higher and higher requirements for co...
READ MOREAs the saying goes, a good horse needs a good saddle, and a good home appliance needs a good socket. High-quality socket...
READ MORE