Two hundred amps is not a load you cycle on and off. It runs continuously. Generator output panels. Temporary power dist...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 140 | 173 |
| b | 116 | 144 | |
| c | 43.5 | 57 | |
| d | 38.5 | 51 | |
| e | 17.5 | 25 | |
| f | 47 | 62 | |
| g | 58 | 80.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 140 | 173 |
| b | 116 | 144 | |
| c | 43.5 | 57 | |
| d | 38.5 | 51 | |
| e | 17.5 | 25 | |
| f | 47 | 62 | |
| g | 58 | 80.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 140 | 173 |
| b | 116 | 144 | |
| c | 49.5 | 57 | |
| d | 43.5 | 51 | |
| e | 21.5 | 25 | |
| f | 52 | 62 | |
| g | 66.7 | 80.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 144 | 173 |
| b | 121 | 144 | |
| c | 56 | 63.3 | |
| d | 50 | 56.5 | |
| e | 26.5 | 30.3 | |
| f | 60 | 68.7 | |
| g | 75 | 89 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~ 3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 138 | 170 |
| b | 115 | 141 | |
| c | 24.7 | 32.5 | |
| d | 70.2 | 93.3 | |
| e | 38.3 | 51 | |
| f | 17.5 | 25 | |
| g | 47 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 138 | 170 |
| b | 115 | 141 | |
| c | 24.7 | 32.5 | |
| d | 70.2 | 93.3 | |
| e | 38.3 | 51 | |
| f | 17.5 | 25 | |
| g | 47 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 144 | 170 |
| b | 120.5 | 141 | |
| c | 25.2 | 32.5 | |
| d | 78 | 93.3 | |
| e | 43.8 | 51 | |
| f | 21.5 | 25 | |
| g | 52.2 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 144 | 177 |
| b | 120.5 | 148 | |
| c | 25.2 | 32.5 | |
| d | 87 | 101 | |
| e | 50.2 | 56.5 | |
| f | 26.5 | 30.3 | |
| g | 60 | 68.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Two hundred amps is not a load you cycle on and off. It runs continuously. Generator output panels. Temporary power dist...
READ MORE
Low voltage does not mean low hazard. A 24V control circuit. A 48V battery bank connection. A 110V site safety supply. T...
READ MORE
Sixty-three amps is not a light load. That current runs distribution boards, stage lighting rigs, construction site tran...
READ MORE
Factories run on electricity. Data centers. Construction sites. Shipyards. Event stages. Anywhere heavy equipment plugs ...
READ MORE