Setting up a strong and safe electrical system outdoors is a complex job. Two key parts of this system are the Outdoor D...
READ MORE 
 | Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 74 | 91 | 
| b | 70 | 88 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 55 | 55 | |
| f | 56 | 56 | |
| g | 56 | 56 | |
| h | 24 | 29 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A | 
| Voltage(V): | 110-130V~2P+E | 
| Protection degree: | IP44 | 

 
 | Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 74 | 91 | 
| b | 70 | 88 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 55 | 55 | |
| f | 56 | 56 | |
| g | 56 | 56 | |
| h | 24 | 29 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A | 
| Voltage(V): | 220-240V~2P+E | 
| Protection degree: | IP44 | 

 
 | Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 76 | 90 | 
| b | 80 | 87 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 55 | 55 | |
| f | 56 | 56 | |
| g | 56 | 56 | |
| h | 25 | 30 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A | 
| Voltage(V): | 380-415V~3P+E | 
| Protection degree: | IP44 | 

 
 | Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 76 | 93 | 
| b | 86 | 95 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 55 | 55 | |
| f | 56 | 56 | |
| g | 56 | 56 | |
| h | 26 | 28 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A. 32A | 
| Voltage(V): | 220-380V~/240-415V~3P+N+E | 
| Protection degree: | IP44 | 

 
 | Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 | 
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 54.5 | 68 | |
| f | 88 | 96 | |
| g | 114 | 129 | |
| h | 108 | 122 | |
| i | 75 | 90 | |
| Cable nominal cross-section area(mm²) | 6-25 | 25-70 | |
| Current(A): | 63A. 125A | 
| Voltage(V): | 220-240V~2P+E | 
| Protection degree: | IP67 | 

 
 | Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 100 | 120 | 
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 54.5 | 68 | |
| f | 88 | 96 | |
| g | 114 | 129 | |
| h | 108 | 122 | |
| i | 75 | 90 | |
| Cable nominal cross-section area(mm²) | 6-25 | 25-70 | |
| Current(A): | 63A. 125A | 
| Voltage(V): | 380-415V~3P+E | 
| Protection degree: | IP67 | 

 
 | Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 100 | 120 | 
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 54.5 | 68 | |
| f | 88 | 96 | |
| g | 114 | 129 | |
| h | 108 | 122 | |
| i | 75 | 90 | |
| Cable nominal cross-section area(mm²) | 6-25 | 25-70 | |
| Current(A): | 63A. 125A | 
| Voltage(V): | 220-380V~/240-415V~3P+N+E | 
| Protection degree: | IP67 | 

 
                 
                        
                        Setting up a strong and safe electrical system outdoors is a complex job. Two key parts of this system are the Outdoor D...
READ MORE 
                        
                        In today's industrial world, power is everything. Machines, tools, and computers need a constant and safe supply of elec...
READ MORE 
                        
                        In many industrial places, safe and efficient power distribution needs equipment that works well and can adapt. An Outdo...
READ MORE 
                        
                        For industrial work in difficult outdoor areas, having safe and steady power is very important. Outdoor Distribution Box...
READ MORE