Big electrical systems need more than just big transformers and switchgear. They also need good connection parts like In...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 73.5 | 85 | |
| b | 64 | 85 | |
| c | 60 | 70 | |
| d | 52 | 70 | |
| e | 5.5 | 5.5 | |
| f | 44.9 | 54.3 | |
| g | 7 | 8 | |
| g1 | 2 | 2 | |
| h | 86.7 | 98.7 | |
| i | 45.7 | 57.9 | |
| j | 52 | 68 | |
| k | 61 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 73.5 | 85 | |
| b | 64 | 85 | |
| c | 60 | 70 | |
| d | 52 | 70 | |
| e | 5.5 | 5.5 | |
| f | 44.9 | 54.3 | |
| g | 7 | 8 | |
| g1 | 2 | 2 | |
| h | 86.7 | 98.7 | |
| i | 45.7 | 57.9 | |
| j | 52 | 68 | |
| k | 61 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 85 | 85 | |
| b | 85 | 85 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 5.5 | 5.5 | |
| f | 40.3 | 54.3 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 92.4 | 98.7 | |
| i | 51.5 | 57.9 | |
| j | 58 | 68 | |
| k | 65 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 85 | 85 | |
| b | 85 | 85 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 5.5 | 5.5 | |
| f | 41.6 | 55.5 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 97.2 | 111.2 | |
| i | 51.9 | 58.2 | |
| j | 67 | 73 | |
| k | 72 | 84 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a1 | 20° |
| a | 110 | |
| b | 106 | |
| c | 85 | |
| d | 77 | |
| e | 6.2 | |
| f | 69 | |
| g | 12 | |
| g1 | 2 | |
| h | 122 | |
| i | 85 | |
| j | 70 | |
| k | 95 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a1 | 20° |
| a | 110 | |
| b | 106 | |
| c | 85 | |
| d | 77 | |
| e | 6.2 | |
| f | 69 | |
| g | 12 | |
| g1 | 2 | |
| h | 122 | |
| i | 85 | |
| j | 70 | |
| k | 95 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a1 | 20° |
| a | 110 | |
| b | 106 | |
| c | 85 | |
| d | 77 | |
| e | 6.2 | |
| f | 69 | |
| g | 12 | |
| g1 | 2 | |
| h | 122 | |
| i | 85 | |
| j | 70 | |
| k | 95 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a1 | 20° |
| a | 110 | |
| b | 106 | |
| c | 85 | |
| d | 77 | |
| e | 6.2 | |
| f | 69 | |
| g | 12 | |
| g1 | 2 | |
| h | 122 | |
| i | 85 | |
| j | 70 | |
| k | 95 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 73.5 | 73.5 | |
| b | 64 | 64 | |
| c | 60 | 60 | |
| d | 52 | 52 | |
| e | 5.5 | 5.5 | |
| f | 42.9 | 55.5 | |
| g | 7 | 8 | |
| g1 | 2 | 2 | |
| h | 82.6 | 108.9 | |
| i | 51.7 | 63.2 | |
| j | 52 | 68 | |
| k | 61 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 73.5 | 73.5 | |
| b | 64 | 64 | |
| c | 60 | 60 | |
| d | 52 | 52 | |
| e | 5.5 | 5.5 | |
| f | 42.9 | 55.5 | |
| g | 7 | 8 | |
| g1 | 2 | 2 | |
| h | 82.6 | 108.9 | |
| i | 51.7 | 63.2 | |
| j | 52 | 68 | |
| k | 61 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 85 | 85 | |
| b | 85 | 85 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 5.5 | 5.5 | |
| f | 40.3 | 55.5 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 88.6 | 108.9 | |
| i | 56.2 | 63.2 | |
| j | 58 | 68 | |
| k | 65 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 85 | 85 | |
| b | 85 | 85 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 5.5 | 5.5 | |
| f | 41.6 | 55.5 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 96 | 109 | |
| i | 58.6 | 63.2 | |
| j | 67 | 73 | |
| k | 72 | 84 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Big electrical systems need more than just big transformers and switchgear. They also need good connection parts like In...
READ MORE
Production layouts change more frequently than before. Manufacturing lines are adjusted to accommodate new orders, tempo...
READ MORE
More and more places these days are using their own local power systems. Things like business parks, university campuses...
READ MORE
Small hardware decisions can ripple through a facility’s daily rhythm. Fixing power feed points where equipment routinel...
READ MOREStraight panel outlets are fine on roomy enclosures. In compact control cabinets, crowded distribution panels, or skid-mounted systems, however, the space behind the door disappears quickly. A Panel Mounted Angle Socket solves a very practical problem: it redirects the cable exit so conductors don't have to fight the enclosure, making wiring neater, closure easier, and maintenance less frustrating over the life of the equipment.
1) More clearance where it matters most: behind the panel
Angled outlets help installers route cables without pushing them into sharp bends.
For production builds, that often translates into quicker wiring and fewer "open it back up" corrections.
2) A cleaner front face—and fewer knocks in busy work zones
Industrial panels live in places where cables get dragged, bumped, and snagged.
Small geometry changes can make day-to-day handling noticeably smoother.
3) Low-voltage certified and multi-voltage options: useful for standard platforms
Many builders reuse one enclosure concept across multiple projects or regions. Choosing a Panel Mounted Angle Socket family that includes certified low-voltage versions and multi-voltage selections can help you:
That kind of planning reduces SKU sprawl and keeps field support simpler.
4) Pre-spec checks that prevent fitment surprises
Before finalizing a part number, a quick design review avoids the common headaches:
These checks cost minutes on paper and save hours in rework.
A Panel Mounted Angle Socket is a straightforward upgrade that improves rear clearance, protects cables from unnecessary strain, and makes panels easier to assemble and service—especially in compact or high-density builds. For manufacturers aiming to keep one cabinet design compatible across different voltage needs, angled panel-mounted sockets also support cleaner standardization and smoother long-term maintenance. For dependable production supply and consistent industrial connector solutions, partner with WENZHOU SHANGFENG ELECTRIC CO., LTD.