Factories run on electricity. Data centers. Construction sites. Shipyards. Event stages. Anywhere heavy equipment plugs ...
READ MORE
| Earth contact position | 4h | |
| Pole | 2P+E | |
| Dimension(mm) | a | 111 |
| b | 47 | |
| c | 50 | |
| d | 47 | |
| e | 39 | |
| Cable nominal cross-section area(mm²) | 1-1.5 | |
| Current(A): | 16A/10-16A |
| Voltage(V): | 220-130V~2P+E |
| Protection degree: | IP20 |

| Earth contact position | 6h | |
| Pole | 2P+E | |
| Dimension(mm) | a | 111 |
| b | 47 | |
| c | 54 | |
| d | 51 | |
| e | 43 | |
| f | 38 | |
| Cable nominal cross-section area(mm²) | 1-1.5 | |
| Current(A): | 16A/10-16A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP20 |

| Earth contact position | 6h | |
| Pole | 2P+E | |
| Dimension(mm) | a | 111 |
| b | 47 | |
| c | 54 | |
| d | 51 | |
| e | 21 | |
| Cable nominal cross-section area(mm²) | 1-1.5 | |
| Current(A): | 16A/10-16A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP20 |

| Earth contact position | 4h | |
| Pole | 2P+E | |
| Dimension(mm) | a | 91 |
| b | 100 | |
| c | 54 | |
| d | 69 | |
| e | 55 | |
| f | 106 | |
| Cable nominal cross-section area(mm²) | 1-1.5 | |
| Current(A): | 16A/10-16A |
| Voltage(V): | 100-130V~2P+E |
| Protection degree: | IP20 |

| Earth contact position | 6h | |
| Pole | 2P+E | |
| Dimension(mm) | a | 90 |
| b | 100 | |
| c | 54 | |
| d | 69 | |
| e | 55 | |
| f | 106 | |
| Cable nominal cross-section area(mm²) | 1-1.5 | |
| Current(A): | 16A/10-16A |
| Voltage(V): | 200-250V~2P+E |
| Protection degree: | IP20 |

| Pole | 3 | |
| Dimension(mm) | a | 104 |
| b | 42 | |
| c | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | |
| Current(A): | 16A |
| Voltage(V): | 200-240V~2P+E |
| Protection degree: | IP44 |

| Pole | 3 | |
| Dimension(mm) | a | 131 |
| b | 57 | |
| c | 5 | |
| d | 46 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | |
| Current(A): | 16A |
| Voltage(V): | 200-240V~2P+E |
| Protection degree: | IP44 |

| Pole | 3 | |
| Dimension(mm) | a | 54 |
| b | 73 | |
| c | 64 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | |
| Current(A): | 16A |
| Voltage(V): | 200-240V~2P+E |
| Protection degree: | IP44 |

| Pole | 3 | |
| Dimension(mm) | a | 50.6 |
| b | 65 | |
| c | 41 | |
| d | 26 | |
| e | 38.5 | |
| f | 38.5 | |
| g | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | |
| Current(A): | 16A |
| Voltage(V): | 200-240V~2P+E |
| Protection degree: | IP44 |

| Pole | 3 | |
| Dimension(mm) | a | 50.6 |
| b | 65 | |
| c | 41 | |
| d | 26 | |
| e | 38.5 | |
| f | 38.5 | |
| g | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | |
| Current(A): | 16A |
| Voltage(V): | 200-240V~2P+E |
| Protection degree: | IP44 |

| Pole | 3 | |
| Dimension(mm) | a | 50.6 |
| b | 65 | |
| c | 41 | |
| d | 26 | |
| e | 38.5 | |
| f | 38.5 | |
| g | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | |
| Current(A): | 16A |
| Voltage(V): | 200-240V~2P+E |
| Protection degree: | IP55 |

| Code: | SFN-312M |
|
Nominal current(A): |
10A |
| Nominal voltage(V): | 220-240V~ |
| No.poles: | 2P+E |
| Protection degree: | IP44 |
Factories run on electricity. Data centers. Construction sites. Shipyards. Event stages. Anywhere heavy equipment plugs ...
READ MORE
Electrical outlets in harsh environments need more than just a cover. Rain, dust, pressure washing, humidity—exposure ki...
READ MORE
At 200 amps, you are feeding a distribution board, a generator tap box, or a temporary power setup for an entire site se...
READ MORE
An industrial socket without an interlock is just a live hole. A mechanical interlocking socket adds a physical gate. Th...
READ MOREOn industrial sites, the socket is rarely "just a socket." It's a decision point that affects downtime, maintenance speed, and operator safety. A well-chosen Multifunctional Industrial Socket can simplify power access across mixed equipment, while a properly specified Single Phase Industrial Socket keeps everyday loads stable and predictable.
What "Multifunctional" Really Means (and why it matters)
In practice, "multifunctional" usually refers to a socket solution that supports more than one real installation need, such as:
The advantage is operational: you reduce the number of different outlets you must stock, maintain, and train people to use correctly—especially in facilities with rotating equipment and temporary setups.
Single-Phase Industrial Sockets: where they fit best
Single-phase power is common for many day-to-day loads, such as:
A Single Phase Industrial Socket becomes "industrial-grade" when it's selected and installed to match the load profile, duty cycle, and environmental exposure—not just the plug shape.
Key Selection Checks (the ones engineers actually use)
When comparing industrial sockets, these checkpoints prevent most site problems: