| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 140 | 173 |
| b | 116 | 144 | |
| c | 43.5 | 57 | |
| d | 38.5 | 51 | |
| e | 17.5 | 25 | |
| f | 47 | 62 | |
| g | 58 | 80.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 140 | 173 |
| b | 116 | 144 | |
| c | 43.5 | 57 | |
| d | 38.5 | 51 | |
| e | 17.5 | 25 | |
| f | 47 | 62 | |
| g | 58 | 80.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 140 | 173 |
| b | 116 | 144 | |
| c | 49.5 | 57 | |
| d | 43.5 | 51 | |
| e | 21.5 | 25 | |
| f | 52 | 62 | |
| g | 66.7 | 80.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 144 | 173 |
| b | 121 | 144 | |
| c | 56 | 63.3 | |
| d | 50 | 56.5 | |
| e | 26.5 | 30.3 | |
| f | 60 | 68.7 | |
| g | 75 | 89 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a | 238.9 |
| b | 179.4 | |
| c | 66 | |
| d | 100.1 | |
| e | 75.5 | |
| f | 36.5 | |
| g | 69.5 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~ 3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 138 | 170 |
| b | 115 | 141 | |
| c | 24.7 | 32.5 | |
| d | 70.2 | 93.3 | |
| e | 38.3 | 51 | |
| f | 17.5 | 25 | |
| g | 47 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 138 | 170 |
| b | 115 | 141 | |
| c | 24.7 | 32.5 | |
| d | 70.2 | 93.3 | |
| e | 38.3 | 51 | |
| f | 17.5 | 25 | |
| g | 47 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 144 | 170 |
| b | 120.5 | 141 | |
| c | 25.2 | 32.5 | |
| d | 78 | 93.3 | |
| e | 43.8 | 51 | |
| f | 21.5 | 25 | |
| g | 52.2 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 144 | 177 |
| b | 120.5 | 148 | |
| c | 25.2 | 32.5 | |
| d | 87 | 101 | |
| e | 50.2 | 56.5 | |
| f | 26.5 | 30.3 | |
| g | 60 | 68.7 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

The Shell Material Sets the Baseline Many 63A plugs use PA6 nylon or a similar polyamide for the housing. The material h...
READ MORE
A portable socket sits on the end of an extension cord. You move it where you need it. A wall mounted industrial socket ...
READ MORE
Standard wall outlets deliver single-phase power. Enough for lights and computers. Industrial equipment needs more. Moto...
READ MORE
Standard plugs handle 10, 15, maybe 30 amps. But industrial equipment needs more. Welders. Large compressors. Temporary ...