Big electrical systems need more than just big transformers and switchgear. They also need good connection parts like In...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | axb | 75 | 75 |
| cxd | 61 | 61 | |
| e | 22 | 24 | |
| f | 60 | 70 | |
| g | 5 | 5 | |
| h | 50 | 55 | |
| i | 87 | 95 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | axb | 75 | 75 |
| cxd | 61 | 61 | |
| e | 22 | 24 | |
| f | 60 | 70 | |
| g | 5 | 5 | |
| h | 50 | 55 | |
| i | 87 | 95 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | axb | 75 | 75 |
| cxd | 61 | 61 | |
| e | 17 | 24 | |
| f | 59 | 69 | |
| g | 5 | 5 | |
| h | 50 | 55 | |
| i | 88 | 95 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | axb | 75 | 75 |
| cxd | 61 | 61 | |
| e | 17 | 22 | |
| f | 59 | 71 | |
| g | 5 | 5 | |
| h | 55 | 60 | |
| i | 92 | 100 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 18 | 24 | |
| f | 63 | 70 | |
| g | 50 | 55 | |
| h | 50 | 55 | |
| i | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 18 | 24 | |
| f | 63 | 70 | |
| g | 50 | 55 | |
| h | 50 | 55 | |
| i | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 18 | 24 | |
| f | 63 | 70 | |
| g | 50 | 55 | |
| h | 50 | 55 | |
| i | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 18 | 24 | |
| f | 63 | 76 | |
| g | 55 | 60 | |
| h | 55 | 60 | |
| i | 5 | 5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 35 | 44 | |
| f | 96 | 106 | |
| g | 80 | 100 | |
| h | 80 | 100 | |
| i | 7 | 7 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A,125A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 35 | 44 | |
| f | 96 | 106 | |
| g | 80 | 100 | |
| h | 80 | 100 | |
| i | 7 | 7 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-250V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 35 | 44 | |
| f | 96 | 106 | |
| g | 80 | 100 | |
| h | 80 | 100 | |
| i | 7 | 7 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 35 | 44 | |
| f | 96 | 106 | |
| g | 80 | 100 | |
| h | 80 | 100 | |
| i | 7 | 7 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Big electrical systems need more than just big transformers and switchgear. They also need good connection parts like In...
READ MORE
Production layouts change more frequently than before. Manufacturing lines are adjusted to accommodate new orders, tempo...
READ MORE
More and more places these days are using their own local power systems. Things like business parks, university campuses...
READ MORE
Small hardware decisions can ripple through a facility’s daily rhythm. Fixing power feed points where equipment routinel...
READ MOREA panel socket is more than a power point—it's a repeat-touch component that gets plugged, unplugged, bumped, and serviced under time pressure. When specifying a Second Generation Upgraded Pannel Mounted Straight socket, two details often determine whether the installation stays trouble-free: keying (clock position) and cable compatibility. Using SFN-313-4 / SFN-3234-4 as a reference (110–130V, 2P+E, 4h, 16A/32A, IP44), here's how buyers and electricians typically evaluate the right fit.
4h earth position: a simple way to reduce wrong connections
Clock-position keying is designed to prevent mismating between different systems.
In real installations, this mechanical separation can be as valuable as labeling—especially on temporary power boards and busy panels.
Cable range: installation speed and long-term reliability
Cable range is not a minor convenience; it affects termination quality.
For panel builders, this translates into faster assembly and fewer field call-backs.
IP44 in practice: what it covers—and what it doesn't
An IP44 panel-mounted socket is usually chosen for:
If the panel face is frequently exposed to heavy water jets or persistent wet conditions, stepping up to higher IP protection is typically the safer lifecycle move.
Planning ahead: from 16A/32A today to 125A tomorrow
Many projects start with smaller auxiliary feeds and later expand to higher-current distribution. If your roadmap may require a 125A Industrial Socket (or 125 Amp Industrial Socket), planning early helps:
Even if the initial build uses SFN-313-4 / SFN-3234-4 at 16A/32A, thinking ahead prevents costly panel redesigns later.
For panel applications, the most reliable choice is the one that matches system voltage, uses the correct 4h keying, supports the right cable range, and offers adequate IP protection for the environment. A Second Generation Upgraded Pannel Mounted Straight socket specified this way installs faster, mates correctly, and stays stable in service—while keeping a clear path for future upgrades up to a 125A Industrial Socket / 125 Amp Industrial Socket requirement.