A 63A industrial plug is not the plug on a household extension cord. It runs the distribution boards, the stage lighting...
READ MORE
| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 25 | 30 | |
| f | 41 | 50 | |
| g | 5 | 5 | |
| h | 43 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 61 | 61 | |
| d | 61 | 61 | |
| e | 26 | 30 | |
| f | 42 | 50 | |
| g | 5 | 5 | |
| h | 55 | 55 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 64 | 73 | |
| e | 74 | 98 | |
| f | 40 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 64 | 73 | |
| e | 74 | 98 | |
| f | 40 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 65 | 73 | |
| e | 83 | 98 | |
| f | 48 | 54 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 61 | 61 | |
| d | 65 | 73 | |
| e | 90 | 103 | |
| f | 53 | 61 | |
| g | 5.5 | 5.5 | |
| Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 | |
| Current(A): | 16A, 32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

| Earth contact position | 4h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 3 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 4 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 63 | 125 | |
| Pole | 5 | ||
| Dimension(mm) | a | 100 | 120 |
| b | 100 | 120 | |
| c | 80 | 101 | |
| d | 80 | 101 | |
| e | 13 | 22 | |
| f | 99 | 110 | |
| g | 73 | 84 | |
| h | 73 | 84 | |
| i | 6 | 6 | |
| Cable nominal cross-section area(mm²) | 6-16 | 16-50 | |
| Current(A): | 63A, 125A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

A 63A industrial plug is not the plug on a household extension cord. It runs the distribution boards, the stage lighting...
READ MORE
High-performance 200A industrial power plugs are seeing demand from data centers, large manufacturing plants, and tempor...
READ MORE
The voltage is low. The current is not. A 24V control circuit can carry 16 amps or more, and a loose connection at that ...
READ MORE
63A industrial plug factories are seeing steady demand from construction sites, manufacturing plants, and temporary powe...
READ MOREChoosing a Second Generation Industrial Implement Socket isn't about adding complexity—it's about improving reliability where equipment takes the most abuse: at the connection point. In agriculture and off‑road applications, the goal is simple: consistent power and signals despite vibration, contamination, and repetitive connect/disconnect cycles.
What Makes Second-Generation Sockets Worth Specifying
Second-generation designs typically focus on practical upgrades that reduce common field failures:
Typical Use Cases (Where the Upgrade Pays Off)
A Second Generation Industrial Implement Socket is commonly specified for:
Spec Checklist: How to Avoid Downtime from the Start
Before selecting a socket, verify these points (the boring checks that prevent expensive service calls):
The right Second Generation Industrial Implement Socket helps keep lighting, auxiliary power, and implement functions consistent when conditions are harsh and schedules are tight. Specify for the real environment—vibration, contamination, and frequent coupling—and you'll reduce intermittent faults that quietly drain uptime.