READ MOREEarth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 140 | 173 |
b | 116 | 144 | |
c | 43.5 | 57 | |
d | 38.5 | 51 | |
e | 17.5 | 25 | |
f | 47 | 62 | |
g | 58 | 80.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 140 | 173 |
b | 116 | 144 | |
c | 43.5 | 57 | |
d | 38.5 | 51 | |
e | 17.5 | 25 | |
f | 47 | 62 | |
g | 58 | 80.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 140 | 173 |
b | 116 | 144 | |
c | 49.5 | 57 | |
d | 43.5 | 51 | |
e | 21.5 | 25 | |
f | 52 | 62 | |
g | 66.7 | 80.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 144 | 173 |
b | 121 | 144 | |
c | 56 | 63.3 | |
d | 50 | 56.5 | |
e | 26.5 | 30.3 | |
f | 60 | 68.7 | |
g | 75 | 89 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Earth contact position | 4h | |
Rated current(A) | 63 | |
Pole | 3 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 3 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 4 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 5 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 220-380V~/240-415V~ 3P+N+E |
Protection degree: | IP44 |
Earth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 138 | 170 |
b | 115 | 141 | |
c | 24.7 | 32.5 | |
d | 70.2 | 93.3 | |
e | 38.3 | 51 | |
f | 17.5 | 25 | |
g | 47 | 62.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 138 | 170 |
b | 115 | 141 | |
c | 24.7 | 32.5 | |
d | 70.2 | 93.3 | |
e | 38.3 | 51 | |
f | 17.5 | 25 | |
g | 47 | 62.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 144 | 170 |
b | 120.5 | 141 | |
c | 25.2 | 32.5 | |
d | 78 | 93.3 | |
e | 43.8 | 51 | |
f | 21.5 | 25 | |
g | 52.2 | 62.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 144 | 177 |
b | 120.5 | 148 | |
c | 25.2 | 32.5 | |
d | 87 | 101 | |
e | 50.2 | 56.5 | |
f | 26.5 | 30.3 | |
g | 60 | 68.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP67 |
In many industrial and construction settings, maintaining consistent and organized power distribution is critical for bo...
READ MOREEnsuring consistent electrical connections in demanding industrial environments requires thoughtful component selection ...
READ MOREConstruction sites are a fast-changing environment, where safety, reliability and efficiency are always key factors for ...
READ MOREIndustrial power distribution systems require rugged plugs, high-current plugs and receptacles, and multi-receptacle con...
READ MORE