Construction sites are a fast-changing environment, where safety, reliability and efficiency are always key factors for ...
READ MOREEarth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 137 | 153 |
b | 87 | 101 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 137 | 153 |
b | 87 | 101 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 139 | 153 |
b | 95 | 101 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 138 | 154 |
b | 99 | 104 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Earth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 151 | 165 |
b | 96 | 107 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 151 | 165 |
b | 96 | 107 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 155 | 165 |
b | 98 | 107 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 153 | 166 |
b | 103 | 109 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP67 |
Earth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 151 | 165 |
b | 96 | 107 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 151 | 165 |
b | 96 | 107 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 155 | 165 |
b | 98 | 107 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 153 | 166 |
b | 103 | 109 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP67 |
Construction sites are a fast-changing environment, where safety, reliability and efficiency are always key factors for ...
READ MOREIndustrial power distribution systems require rugged plugs, high-current plugs and receptacles, and multi-receptacle con...
READ MOREWith the continuous development of automation technology, industrial equipment has higher and higher requirements for co...
READ MOREAs the saying goes, a good horse needs a good saddle, and a good home appliance needs a good socket. High-quality socket...
READ MORE