Construction sites are a fast-changing environment, where safety, reliability and efficiency are always key factors for ...
READ MOREEarth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 155 | 195.9 |
b | 81 | 102.7 | |
c | 51.1 | 64.2 | |
d | 49.5 | 64.2 | |
e | 86 | 101.8 | |
f | 34.7 | 37 | |
g | 57 | 71.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 155 | 195.9 |
b | 81 | 102.7 | |
c | 51.1 | 64.2 | |
d | 49.5 | 64.2 | |
e | 86 | 101.8 | |
f | 34.7 | 37 | |
g | 57 | 71.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 155 | 195.9 |
b | 81 | 102.7 | |
c | 51.2 | 64.2 | |
d | 55.7 | 64.2 | |
e | 90.4 | 101.8 | |
f | 37 | 37 | |
g | 61.2 | 71.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 160 | 195 |
b | 86 | 103.2 | |
c | 51 | 62.8 | |
d | 63 | 70.8 | |
e | 97.2 | 104.9 | |
f | 37 | 37 | |
g | 75.5 | 80 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Earth contact position | 4h | |
Rated current(A) | 63 | |
Pole | 3 | |
Dimension(mm) | a | 257 |
b | 112.5 | |
c | 85 | |
d | 77.4 | |
e | 108 | |
f | 34 | |
g | 92 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 16A,32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 3 | |
Dimension(mm) | a | 257 |
b | 112.5 | |
c | 85 | |
d | 77.4 | |
e | 108 | |
f | 34 | |
g | 92 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 4 | |
Dimension(mm) | a | 257 |
b | 112.5 | |
c | 85 | |
d | 77.4 | |
e | 108 | |
f | 34 | |
g | 92 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 5 | |
Dimension(mm) | a | 257 |
b | 112.5 | |
c | 85 | |
d | 77.4 | |
e | 108 | |
f | 34 | |
g | 92 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Earth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 158.6 | 199.2 |
b | 81 | 102.7 | |
c | 54.7 | 67.5 | |
d | 49.5 | 64.2 | |
e | 71.7 | 95.5 | |
f | 79.6 | 98.7 | |
g | 34.7 | 37 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 158.6 | 199.2 |
b | 81 | 102.7 | |
c | 54.7 | 67.5 | |
d | 49.5 | 64.2 | |
e | 71.7 | 95.5 | |
f | 79.6 | 98.7 | |
g | 34.7 | 37 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 158.6 | 199.2 |
b | 80.6 | 102.7 | |
c | 54.9 | 67.5 | |
d | 55.7 | 64.2 | |
e | 80.6 | 95.5 | |
f | 85.2 | 98.7 | |
g | 37 | 37 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 142 | 200 |
b | 119 | 103.2 | |
c | 56 | 67.8 | |
d | 63 | 70.8 | |
e | 89 | 102 | |
f | 92.8 | 104.9 | |
g | 37 | 37 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP67 |
Construction sites are a fast-changing environment, where safety, reliability and efficiency are always key factors for ...
READ MOREIndustrial power distribution systems require rugged plugs, high-current plugs and receptacles, and multi-receptacle con...
READ MOREWith the continuous development of automation technology, industrial equipment has higher and higher requirements for co...
READ MOREAs the saying goes, a good horse needs a good saddle, and a good home appliance needs a good socket. High-quality socket...
READ MORE