Industrial Plugs and High Current Plugs And Sockets are very important for places that need power all the time. To make ...
READ MORE
| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 73.5 | 85 | |
| b | 64 | 85 | |
| c | 60 | 70 | |
| d | 52 | 70 | |
| e | 5.5 | 5.5 | |
| f | 44.9 | 54.3 | |
| g | 7 | 8 | |
| g1 | 2 | 2 | |
| h | 86.7 | 98.7 | |
| i | 45.7 | 57.9 | |
| j | 52 | 68 | |
| k | 61 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 73.5 | 85 | |
| b | 64 | 85 | |
| c | 60 | 70 | |
| d | 52 | 70 | |
| e | 5.5 | 5.5 | |
| f | 44.9 | 54.3 | |
| g | 7 | 8 | |
| g1 | 2 | 2 | |
| h | 86.7 | 98.7 | |
| i | 45.7 | 57.9 | |
| j | 52 | 68 | |
| k | 61 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 85 | 85 | |
| b | 85 | 85 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 5.5 | 5.5 | |
| f | 40.3 | 54.3 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 92.4 | 98.7 | |
| i | 51.5 | 57.9 | |
| j | 58 | 68 | |
| k | 65 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 85 | 85 | |
| b | 85 | 85 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 5.5 | 5.5 | |
| f | 41.6 | 55.5 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 97.2 | 111.2 | |
| i | 51.9 | 58.2 | |
| j | 67 | 73 | |
| k | 72 | 84 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a1 | 20° |
| a | 110 | |
| b | 106 | |
| c | 85 | |
| d | 77 | |
| e | 6.2 | |
| f | 69 | |
| g | 12 | |
| g1 | 2 | |
| h | 122 | |
| i | 85 | |
| j | 70 | |
| k | 95 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a1 | 20° |
| a | 110 | |
| b | 106 | |
| c | 85 | |
| d | 77 | |
| e | 6.2 | |
| f | 69 | |
| g | 12 | |
| g1 | 2 | |
| h | 122 | |
| i | 85 | |
| j | 70 | |
| k | 95 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a1 | 20° |
| a | 110 | |
| b | 106 | |
| c | 85 | |
| d | 77 | |
| e | 6.2 | |
| f | 69 | |
| g | 12 | |
| g1 | 2 | |
| h | 122 | |
| i | 85 | |
| j | 70 | |
| k | 95 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a1 | 20° |
| a | 110 | |
| b | 106 | |
| c | 85 | |
| d | 77 | |
| e | 6.2 | |
| f | 69 | |
| g | 12 | |
| g1 | 2 | |
| h | 122 | |
| i | 85 | |
| j | 70 | |
| k | 95 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 73.5 | 73.5 | |
| b | 64 | 64 | |
| c | 60 | 60 | |
| d | 52 | 52 | |
| e | 5.5 | 5.5 | |
| f | 42.9 | 55.5 | |
| g | 7 | 8 | |
| g1 | 2 | 2 | |
| h | 82.6 | 108.9 | |
| i | 51.7 | 63.2 | |
| j | 52 | 68 | |
| k | 61 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 73.5 | 73.5 | |
| b | 64 | 64 | |
| c | 60 | 60 | |
| d | 52 | 52 | |
| e | 5.5 | 5.5 | |
| f | 42.9 | 55.5 | |
| g | 7 | 8 | |
| g1 | 2 | 2 | |
| h | 82.6 | 108.9 | |
| i | 51.7 | 63.2 | |
| j | 52 | 68 | |
| k | 61 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 85 | 85 | |
| b | 85 | 85 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 5.5 | 5.5 | |
| f | 40.3 | 55.5 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 88.6 | 108.9 | |
| i | 56.2 | 63.2 | |
| j | 58 | 68 | |
| k | 65 | 80 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a1 | 20° | 20° |
| a | 85 | 85 | |
| b | 85 | 85 | |
| c | 70 | 70 | |
| d | 70 | 70 | |
| e | 5.5 | 5.5 | |
| f | 41.6 | 55.5 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 96 | 109 | |
| i | 58.6 | 63.2 | |
| j | 67 | 73 | |
| k | 72 | 84 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Industrial Plugs and High Current Plugs And Sockets are very important for places that need power all the time. To make ...
READ MORE
Setting up a strong and safe electrical system outdoors is a complex job. Two key parts of this system are the Outdoor D...
READ MORE
In today's industrial world, power is everything. Machines, tools, and computers need a constant and safe supply of elec...
READ MORE
In many industrial places, safe and efficient power distribution needs equipment that works well and can adapt. An Outdo...
READ MORE