Industrial power distribution systems require rugged plugs, high-current plugs and receptacles, and multi-receptacle con...
READ MOREEarth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 134 | 148 |
b | 80 | 88 | |
c | 71 | 71 | |
d | 43.5 | 57.5 | |
e | 57 | 57 | |
f | 20 | 20 | |
g | 32.5 | 32.5 | |
h | 6.5 | 6.5 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 134 | 148 |
b | 80 | 88 | |
c | 71 | 71 | |
d | 43.5 | 57.5 | |
e | 57 | 57 | |
f | 20 | 20 | |
g | 32.5 | 32.5 | |
h | 6.5 | 6.5 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 139 | 148.5 |
b | 80 | 88 | |
c | 71 | 71 | |
d | 50 | 57 | |
e | 57 | 57 | |
f | 20 | 20 | |
g | 32.5 | 32.5 | |
h | 6.5 | 6.5 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 138.5 | 150.5 |
b | 83 | 90 | |
c | 71 | 71 | |
d | 55 | 64 | |
e | 57 | 57 | |
f | 20 | 20 | |
g | 32.5 | 33.5 | |
h | 6.5 | 6.5 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 56 | 56 |
b | 56 | 56 | |
c | 70.5 | 70.5 | |
d | 70.5 | 70.5 | |
e | 45 | 57 | |
f | 23 | 28 | |
g | 42 | 51 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 56 | 56 |
b | 56 | 56 | |
c | 70.5 | 70.5 | |
d | 70.5 | 70.5 | |
e | 42 | 57 | |
f | 23 | 28 | |
g | 42 | 51 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 56 | 56 |
b | 56 | 56 | |
c | 70.5 | 70.5 | |
d | 70.5 | 70.5 | |
e | 57 | 63 | |
f | 23 | 28 | |
g | 42 | 51 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Industrial power distribution systems require rugged plugs, high-current plugs and receptacles, and multi-receptacle con...
READ MOREWith the continuous development of automation technology, industrial equipment has higher and higher requirements for co...
READ MOREAs the saying goes, a good horse needs a good saddle, and a good home appliance needs a good socket. High-quality socket...
READ MOREThe electrical socket manufacturing industry is undergoing significant changes due to new regulatory trends that influen...
READ MORE