READ MOREEarth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 133 | 150 |
b | 68 | 92 | |
c | 50 | 65 | |
Ø | 6 | 8 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 133 | 150 |
b | 68 | 92 | |
c | 50 | 65 | |
Ø | 6 | 8 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 133 | 150 |
b | 79 | 92 | |
c | 56 | 65 | |
Ø | 6 | 8 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 139 | 154 |
b | 90 | 100 | |
c | 63 | 70.5 | |
Ø | 8 | 8 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 63 | 125 | |
Pole | 3 | ||
Dimension(mm) | a | 240 | 303 |
b | 115 | 128 | |
c | 16-38 | 30-50 | |
d | 108 | 120 | |
Cable nominal cross-section area(mm²) | 6-16 | 16-50 |
Current(A): | 63A. 125A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 63 | 125 | |
Pole | 4 | ||
Dimension(mm) | a | 240 | 303 |
b | 115 | 128 | |
c | 16-38 | 30-50 | |
d | 108 | 120 | |
Cable nominal cross-section area(mm²) | 6-16 | 16-50 |
Current(A): | 63A. 125A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 63 | 125 | |
Pole | 5 | ||
Dimension(mm) | a | 240 | 303 |
b | 115 | 128 | |
c | 16-38 | 30-50 | |
d | 108 | 120 | |
Cable nominal cross-section area(mm²) | 6-16 | 16-50 |
Current(A): | 63A. 125A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP67 |
Earth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 150 | 189 |
b | 68 | 92 | |
c | 50 | 65 | |
Ø | 8 | 10 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 150 | 189 |
b | 68 | 92 | |
c | 50 | 65 | |
Ø | 8 | 10 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 149 | 189 |
b | 79 | 92 | |
c | 56 | 65 | |
Ø | 8 | 10 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 179 | 193 |
b | 90 | 100 | |
c | 63 | 70.5 | |
Ø | 10 | 10 | |
Cable nominal cross-section area(mm²) | 1-2.5 | 2.5-6 |
Current(A): | 16A. 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Construction sites are a fast-changing environment, where safety, reliability and efficiency are always key factors for ...
READ MOREIndustrial power distribution systems require rugged plugs, high-current plugs and receptacles, and multi-receptacle con...
READ MOREWith the continuous development of automation technology, industrial equipment has higher and higher requirements for co...
READ MOREAs the saying goes, a good horse needs a good saddle, and a good home appliance needs a good socket. High-quality socket...
READ MORE