Factories need steady, safe power for machines. The Combination Socket Box is important. It gives power from one central...
READ MOREEarth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 140 | 173 |
b | 116 | 144 | |
c | 43.5 | 57 | |
d | 38.5 | 51 | |
e | 17.5 | 25 | |
f | 47 | 62 | |
g | 58 | 80.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 140 | 173 |
b | 116 | 144 | |
c | 43.5 | 57 | |
d | 38.5 | 51 | |
e | 17.5 | 25 | |
f | 47 | 62 | |
g | 58 | 80.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 140 | 173 |
b | 116 | 144 | |
c | 49.5 | 57 | |
d | 43.5 | 51 | |
e | 21.5 | 25 | |
f | 52 | 62 | |
g | 66.7 | 80.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 144 | 173 |
b | 121 | 144 | |
c | 56 | 63.3 | |
d | 50 | 56.5 | |
e | 26.5 | 30.3 | |
f | 60 | 68.7 | |
g | 75 | 89 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A, 32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP44 |
Earth contact position | 4h | |
Rated current(A) | 63 | |
Pole | 3 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 3 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 4 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP44 |
Earth contact position | 6h | |
Rated current(A) | 63 | |
Pole | 5 | |
Dimension(mm) | a | 238.9 |
b | 179.4 | |
c | 66 | |
d | 100.1 | |
e | 75.5 | |
f | 36.5 | |
g | 69.5 | |
Cable nominal cross-section area(mm²) | 10-16 |
Current(A): | 63A |
Voltage(V): | 220-380V~/240-415V~ 3P+N+E |
Protection degree: | IP44 |
Earth contact position | 4h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 138 | 170 |
b | 115 | 141 | |
c | 24.7 | 32.5 | |
d | 70.2 | 93.3 | |
e | 38.3 | 51 | |
f | 17.5 | 25 | |
g | 47 | 62.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 110-130V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 3 | ||
Dimension(mm) | a | 138 | 170 |
b | 115 | 141 | |
c | 24.7 | 32.5 | |
d | 70.2 | 93.3 | |
e | 38.3 | 51 | |
f | 17.5 | 25 | |
g | 47 | 62.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-240V~2P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 4 | ||
Dimension(mm) | a | 144 | 170 |
b | 120.5 | 141 | |
c | 25.2 | 32.5 | |
d | 78 | 93.3 | |
e | 43.8 | 51 | |
f | 21.5 | 25 | |
g | 52.2 | 62.2 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 380-415V~3P+E |
Protection degree: | IP67 |
Earth contact position | 6h | ||
Rated current(A) | 16 | 32 | |
Pole | 5 | ||
Dimension(mm) | a | 144 | 177 |
b | 120.5 | 148 | |
c | 25.2 | 32.5 | |
d | 87 | 101 | |
e | 50.2 | 56.5 | |
f | 26.5 | 30.3 | |
g | 60 | 68.7 | |
Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 |
Current(A): | 16A,32A |
Voltage(V): | 220-380V~/240-415V~3P+N+E |
Protection degree: | IP67 |
Factories need steady, safe power for machines. The Combination Socket Box is important. It gives power from one central...
READ MOREModern factories need power systems that are stable, work well, and are safe. These systems power many machines. The Com...
READ MOREWorksites and factories need flexible power systems for changing machines. High current plugs and sockets and multi-sock...
READ MOREIn many industrial and construction settings, maintaining consistent and organized power distribution is critical for bo...
READ MORE