| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.8 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 91 | 101.8 | |
| i | 45 | 58 | |
| j | 51.2 | 63 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.8 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 91 | 101.8 | |
| i | 45 | 58 | |
| j | 51.2 | 63 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 32.2 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 92.4 | 101.8 | |
| i | 52 | 58 | |
| j | 51.1 | 63 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.1 | 39.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 97.2 | 111.7 | |
| i | 55 | 62 | |
| j | 52.7 | 62.2 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 107 |
| b | 100 | |
| c | 86 | |
| d | 78 | |
| e | 6 | |
| f | 55 | |
| g | 12 | |
| g1 | 2 | |
| h | 113 | |
| i | 89 | |
| j | 80 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 3 | |
| Dimension(mm) | a | 107 |
| b | 100 | |
| c | 86 | |
| d | 78 | |
| e | 6 | |
| f | 55 | |
| g | 12 | |
| g1 | 2 | |
| h | 113 | |
| i | 89 | |
| j | 80 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 4 | |
| Dimension(mm) | a | 107 |
| b | 100 | |
| c | 86 | |
| d | 78 | |
| e | 6 | |
| f | 55 | |
| g | 12 | |
| g1 | 2 | |
| h | 113 | |
| i | 89 | |
| j | 80 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP44 |

| Earth contact position | 6h | |
| Rated current(A) | 63 | |
| Pole | 5 | |
| Dimension(mm) | a | 107 |
| b | 100 | |
| c | 86 | |
| d | 78 | |
| e | 6 | |
| f | 55 | |
| g | 12 | |
| g1 | 2 | |
| h | 113 | |
| i | 89 | |
| j | 80 | |
| Cable nominal cross-section area(mm²) | 10-16 | |
| Current(A): | 63A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP44 |

| Earth contact position | 4h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.8 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 79.6 | 107.7 | |
| i | 45 | 58 | |
| j | 54.8 | 66.3 | |
| k | 71.7 | 95.5 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 110-130V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 3 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 31.8 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 79.6 | 107.7 | |
| i | 45 | 58 | |
| j | 54.8 | 66.3 | |
| k | 71.7 | 95.5 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-240V~2P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 4 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 32.2 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 85.3 | 107.7 | |
| i | 52 | 58 | |
| j | 54.6 | 66.3 | |
| k | 80.6 | 95.5 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 380-415V~3P+E |
| Protection degree: | IP67 |

| Earth contact position | 6h | ||
| Rated current(A) | 16 | 32 | |
| Pole | 5 | ||
| Dimension(mm) | a | 75 | 75 |
| b | 75 | 75 | |
| c | 60 | 60 | |
| d | 60 | 60 | |
| e | 5.5 | 5.5 | |
| f | 32.2 | 40.8 | |
| g | 8 | 8 | |
| g1 | 2 | 2 | |
| h | 92.9 | 106 | |
| i | 55 | 62 | |
| j | 58.5 | 67.9 | |
| k | 89 | 102 | |
| Cable nominal cross-section area(mm²) | 1.5-2.5 | 4-6 | |
| Current(A): | 16A,32A |
| Voltage(V): | 220-380V~/240-415V~3P+N+E |
| Protection degree: | IP67 |

Industrial Plugs and High Current Plugs And Sockets are very important for places that need power all the time. To make ...
READ MORE
Setting up a strong and safe electrical system outdoors is a complex job. Two key parts of this system are the Outdoor D...
READ MORE
In today's industrial world, power is everything. Machines, tools, and computers need a constant and safe supply of elec...
READ MORE
In many industrial places, safe and efficient power distribution needs equipment that works well and can adapt. An Outdo...
READ MORE